Dual Channel Controller for Gas Detection - DCC

  • Dual Channel Controller for Gas Detection
  • Dual Channel Controller for Gas Detection
  • Dual Channel Controller for Gas Detection
Mouse over image to zoom

• ABS / Polycarbonate
• IP54 rated with splash guard installed.
• Input: One 4-20 mA analog​
• Output​: Two 4-20 mA analog​
• Operating Temperature: -20°C to 40°C (-4°F to 104°F)
• Operating Humidity: 15 - 90% RH non-condensing

  • Model Number: DCC
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

DCC Dual Channel Controller Description
The DCC Dual Channel Controller is a comprehensive and dependable, self-contained system that offers one or two channel configurations for monitoring toxic and combustible gases and PID TVOCs with straight- forward control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications.

Sensor configurations include, two internal electrochemical sensors (one must be CO), or one internal electrochemical and one remote sensor (catalytic or PID) or a remote 4-20 mA analog transmitter. Field configurable settings are done through an easy to navigate, comprehensive menu structure.

Other features include two 4 - 20 mA outputs that can be used for VFD control, one configurable 4 - 20 mA input, two alarm level line voltage, two SPDT dry contact relays with field configurable time delays and trigger levels, a field selectable integral audible alarm and an LCD digital display with LED indicators for channel alarm status and fault conditions.

Automated calibration and other maintenance procedures are simple and easily performed in the field. For parking garage applications, our proprietary Calibration Extending Firmware (CEF) takes into account the aging of the toxic gas sensors so that less frequent calibrations are required.

DCC Dual Channel Controller Key Features
• Single or dual channel operation
• Flexible internal and/or remote sensor conf gurations
• 2x16 character LCD display with LED indicators
• Two 5A SPDT dry contact relays
• Two 4- 20 mA outputs, can be used for VFD control
• One conf gurable 4 - 20 mA input
• Optional loud or water tight, door mounted buzzer
• Thermal resetting fuses
• Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with optional splash guard installed

DCC Dual Channel Controller Application
• Parking Garages requiring VFD control
• Indoor Commerical Swimming Pools
• Firehalls
• Ice Arenas
• Wineries
• ... and many more

DCC Dual Channel Controller Technical Specifications

Gas Type
Electrochemical (internal)
Carbon Monoxide (CO), Nitrogen Dioxide (NO2), Nitric Oxide (NO), 
Oxygen (O2), Hydrogen Sulphide (H2S), Ethylene (C2H4), 
Sulphur Dioxide, (SO2)
Combustible (catalytic)(remote)
Hydrogen (H2), Methane (CH4), Propane (C3H8)
TVOCs PID (remote)


Mechanical
Enclosure
ABS / Polycarbonate, IP54 rated with splash guard installed. 
Copper coated interior to reduce RF interference.
Weight
600 g (1.4 lb)
Size
254 x 218 x 109 mm (10.0 x 8.6 x 4.3 inches)

User Interface
Display
2x16 character LCD digital display with LED Panel 
indicating "CH1" state, "CH2" state, and "FAULT"
"SILENCE" Push Button 
Temporarily clears buzzer / latched relays

Input / Output
Input
One 4-20 mA analog
Output
Two 4-20 mA analog
Relays
Two SPDT dry contact relays, rated 5 amps @ 240 VAC
Audible Alarm
- Standard internal buzzer
- Optional loud, door mounted buzzer, rated 90 dB @ 30 cm (1 ft)
- Optional water tight, door mounted buzzer, rated 85 dB @ 60.96 cm (2 ft)

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service