Differential Pressure Transmitter for Oxygen Pressure Use - MDM490
• Output: 4~20mA, Voltage Output
• Pressure Range: ≤35bar
• Accuracy: ≤0.50%FS
• Other Options: Display
• Pressure Type: Differential
• Diameter: Φ27mm
- Quantity:
- - +
Product Specification
MDM490 Differential Pressure Transmitter Introduction:
MDM490 uses piezoresistive differential pressure sensor as sensing element. Silicon oil is filled in between die and two diaphragms, when measured differential pressure is added on two diaphragm, the pressure could be transferred onto die through silicon oil. Sensor die connects with amplifier circuit through wires, using semi-conductor’s piezoresistive effect, transforming differential pressure signal into electric signal. The whole product is used for differential pressure measurement of petroleum, chemiindustry, power station and hydrology, etc.
MDM490 Differential Pressure Transmitter Environment Condition:
• Shock effect: ≤1% at 3gRMS, 30Hz~2000Hz
• Impact: ≤1% at 100g, 10ms
• Media: liquid or gas which is compatible with construction material
MDM490 Differential Pressure Transmitter Electric Performance:
• Power supply: 2-wire 15V~28V DC; 3-wire 15V~28V DC
• Output signal: 2-wire 4mA~20mA DC; 3-wire 0/1V~5V DC, 0mA~10/20mA DC
• Electrical connection: plug connection or Φ7.2mm 7-pin cable
• Response time(10%~90%): ≤1ms
• Insulation resistor: 100MΩ,500V DC
MDM490 Differential Pressure Transmitter Features:
• Full stainless steel construction, compact size, easy installation;
• Laser welding, full-sealed construction; protection IP65;
• Using piezoresistive differential pressure sensor, 316L isolated diaphragm;
• Temperature compensation and aging, stable performance;
• Zero and span adjustable outside;
• Ex-proof version MDM490 conforms to GB3836.4 Exia Ⅱ CT6 Ga standard;ex-proof certificate is approved;
• Ship-use product conforms to CCS Rules of Classification of Sea-going Steel Ships(2018); ship-use certificate is approved;
• CE and RoHS certificates.
MDM490 Differential Pressure Transmitter Specification:
Range code
0A
02
03
07
08
09
10
12
13
Unit
bar
Measure range
0~0.35
0~0.7
0~1
0~2
0~3.5
0~7
0~10
0~20
0~35
+overpressure
0.7
1.5
2
4
7
14
20
40
70
-overpressure
0.35
0.7
1
2
3.5
7
10
10
10
Max.static pressure
≤200bar
Item*
Min.
Typ.
Max.
Unit
Accuracy
0bar ~ 1bar
0.25
0.5
%FS
2bar ~ 35bar
0.25
0.5
Zero Thermal error
0bar ~ 1bar
0.75
1.25
±%FS, @25℃
2bar ~ 35bar
0.5
0.75
FS Thermal error
0bar ~ 1bar
0.75
1.25
2bar ~ 35bar
0.5
0.75
Stability
≤2bar
0.5
%FS/year
≤35bar
0.2
Static pressure effect
0.05
±%FS, each 1bar
Compensation temp.
0~50
℃
Operation temp.
-30~80 ; -10~70(Cable)
Storage temp.
-40~120; -20~85(Cable)
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃