Dew Point Sensor - NP330-G
• Inline transmitter designed to measure the absolute moisture in gases, in °C dew / frost point (optional ppmW / ppmV)
• Programmable switching output as alarm signal
• Calibrated against cooled mirror dew point meter
• Quality assurance of air-drying systems
• Cost savings during the drying process
• Can be delivered as OEM product
- Quantity:
- - +
Product Specification
Measuring trace humidity in gases
The dew point sensor NP330-G for trace moisture measurement in gases is a 4-20 mA transmitter for measuring absolute humidity in °C dew point or frost point (optional ppmW/ppmV). The measuring range of the sensor covers both, high humidity and trace humidity. The standard measuring range is -80°C FP to +20°C DP (other measuring ranges on request).
The integrated RS232 interface is used for data output and configuration of the sensor. The switching output of the sensor is also programmed via this access.
The high media compatibility creates a wide field of application possibilities as an online measuring device for various gases and gas mixtures. The sensor is used in industrial measurement technology for control, monitoring and quality assurance of air and gas conditioning.
Due to its wide measuring range, the sensor is used for monitoring and controlling refrigeration and adsorption dryers. The NP330-G ensures the quality of air drying systems in production processes and saves energy costs during drying.
Features
• Multipoint calibration (over 60 points)
• Temperature compensation
• High measuring accuracy
• Short response times
• High pressure and shock resistance
• High medium compatibility
• Also available for mil ranges
• Diverse display, transmission and evaluation options
• Mechanical extensions available for different immersion depths (120 mm and 430 mm)
• Calibration certificate according to DIN EN ISO/IEC17025:2018-03
Application fields among others
• Monitoring of air preparation facilities
• Dryer control (refrigeration dryer,adsorption dryer, etc.) • Monitoring of compressors
• Monitoring of laboratories/research facilities
• Production of synthetic materials
• Stock & container control
• Paper & textile industry
• Building services engineering(heating, ventilation, air conditioning)
• Battery cell production
• Pharmaceutical industry
• Food industry
• Residual moisture measurement in gases
Accessories
• Table display
• Mobile data logger P005
• Sensor chamber
• Sensor connection cable
• 1/2 -inch thread adaptor
• PC software autocali
Technical Data
Measuring range dew/frost point |
-80℃ dp to +20℃ dp(other ranges on request) |
Operating temperature |
-20℃ to +60℃ |
Current output |
4–20mA |
Serial interface |
RS232 |
Switching output |
24 V DC / max. 70mA |
Supply |
18-28 V DC / max. 70mA |
Protection type |
IP65 |
Dimension
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Miniature Digital Relative Humidity and Temperature Sensor
-
Probe Style Relative Humidity Sensor Module
-
Capacitive Humidity Sensor
-
Voltage Output Temperature and Humidity Sensor
-
Humidity and Temperature Sensor Module
-
Voltage Output Humidity and Temperature Sensor Module
-
Voltage Output Temperature and Humidity Sensor
-
Temperature Humidity Sensor Module
-
Frequency Output Temperature and Humidity Sensor
-
Capacitive Temperature and Humidity Sensor