Constant Voltage With Cable Differential Pressure Sensor - MEAS DP86CV
• 316L SS
• Wet/Wet Differential
• Low Pressure
• 0 - 100mV Output
• Up to -40℃ to +125℃ Operating Range
• Up to ±0.1% Pressure Non Linearity
• Solid State Reliability
• Low Pressure
- Quantity:
- - +
Product Specification
DP86
Constant Voltage with Cable
• 316L SS
• Wet/Wet Differential
• Low Pressure
• 0 - 100mV Output
The DP86 constant voltage with cable differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing. The DP86 constant voltage with cable is designed for o-ring mounting. The sensing package utilizes silicone oil to transfer pressure from the two 316L stainless steel diaphragms to a single sensing element.
The DP86 constant voltage with cable is designed for high performance, low pressure applications where differential pressure measurement is required. The stainless steel package makes it suitable for use in liquids and corrosive environments.
Please refer to the DP86, uncompensated, non-silicone oil, constant current and constant voltage (fittings and cable design) for more information on different features of the DP86
DP86CV Differential Pressure Sensor Features
• O-Ring Mount
• Up to -40°C to +125°C Operating Range
• Up to ±0.1% Pressure Non Linearity
• Solid State Reliability
• Low Pressure
DP86CV Differential Pressure Sensor Applications
• Level Controls
• Tank Level Measurement
• OEM Equipment
• Corrosive Fluids and Gas Measurement Systems
• Flow Measurements
DP86CV Differential Pressure Sensor Performance Specifications
Supply Voltage: 10Vdc
Ambient Temperature: 25°C (unless otherwise specified)
Notes
Parameters
≤005PSI
≥015PSI
Units
Notes
Min
Typ
Max
Min
Typ
Max
Span
90
100
101
mV
Zero Pressure Output
-2.0
2
2.0
-1.0
0
1.0
mV
1
Pressure Non Linearity
-0.10
0.10
%Span
2
Pressure Hysteresis
-0.10
±0.02
0.10
-0.05
±0.02
0.05
%Span
Repeatability
±0.02
±0.02
%Span
Accuracy RMS of NL,HY,RP
±0.6
±1.0
±0.6
±1.0
%Span
Input Resistance
5500
9000
12500
5500
9000
12500
Ω
Output Resistance
4000
30000
4000
25000
Ω
Temperature Error – Span
-1.5
1.5
-1.0
1.0
%Span
3
Temperature Error – Offset
-2.5
2.5
-1.0
1.0
%Span
3
Thermal Hysteresis – Span
-0.25
±0.05
0.25
-0.25
±0.05
0.25
%Span
3
Thermal Hysteresis – Offset
-0.25
±0.05
0.25
-0.25
±0.05
0.25
%Span
3
Long Term Stability – Span
±0.10
±0.10
%Span/Year
Long Term Stability – Offset
±0.25
±0.10
%Span/Year
Line (Common Mode) Pressure
1000
1000
psi
Line Pressure Effect on Zero
0.5
%Span/1Kpsi
Supply Voltage
10
14
10
14
V
4
Output Load Resistance
5
5
MΩ
5
Insulation Resistance (50Vdc)
50
50
MΩ
6
Output Noise (10Hz to 1KHz)
1.0
1.0
uV p-p
Response Time (10% to 90%)
0.1
0.1
ms
Pressure Overload
3X
Rated
7
Pressure Burst
4X
Rated
7
Compensated Temperature
-20
+85
ºC
Operating Temperature
-40
+125
ºC
8
Storage Temperature
-40
+125
-40
+125
ºC
8
Voltage Breakdown
500V rms @ 50Hz, Leakage Current < 1mA
Shock
50g, 1msec half sine shock per MIL-STD-202G, Method 213B, Condition A
Vibration
±20g MIL-STD 810C, Procedure 514.2, Figure 514.2-2, Curve L
Media – Pressure Port
Liquids and gases compatible with 316/316L Stainless Steel
1. Measured at ambient.
2. Best fit straight line
3. Over the compensated temperature range with respect to 25°C.
4. Guarantees output/input ratiometricity.
5. Load resistance to reduce measurement errors due to output loading.
6. Between case and sensing element.
7. For "H" (high-end) port, rated or 1000psi whichever is less. For "L" (low-end) port rated or 150psi whichever is less. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
8. Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
DP86CV Differential Pressure Sensor Ordering Information
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃