• Sensor element: Pellistor (Catalytic Bead)
• Accuracy: +/-1%
• Resolution: 0.2%
• Response time t90: <15 sec.
• Zero Point variation: 0.5%
• Long-term zero-point drift: <0.5% LEL
• Long-term sensivity drift: <1%
• Temp. range: +20 °C to +50 °C
• Humidity range: 5 to 95% RH non-condensation
- Quantity:
- - +
Product Specification
Combustible gas detector G-series for wall mounting
G-series Combustible Gas Detectors Gases
• Methane, CH4
• Liquid Petroleum Gas, LPG
• Hydrogen, H2
• Propane, C3H8
• Ethylene, C2H4
• Ethyl alcohol, C2H5OH
• Methanol, CH3OH
• Acetone, C3H6O
• Isopropyl alcohol, C3H8O
• Iso/n-Butane, C4H10
• Toluene, C7H8
• Petrol Vapors
On request: other combustible gas detectors
G-series Combustible Gas Detectors Features
• Pellistor (Catalytic Bead) sensor
• Power supply 24 Vdc for output 4-20 mA
• Power supply 24 Vac for output 2-10 Vdc
• Measuring ranges: see ordering on page
• IP65 enclosure with quick locking screws
• Digital measurement value processing incl. temperature compensation
• Internal function control with integrated hardware watchdog
• Data / measured values in micro controller of sensor unit, therefore simple exchange uncalibrated <> calibrated
• High accuracy, selectivity and reliability
• Low zero point drift
• Hardware & software according to SIL2 compliant development process
• Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
G-series Combustible Gas Detectors Options
• LCD display
• LCD display for values & operation, 2 x open-collector for horn & warning lamp.
• Duct mounting set available for sensing combustible gas in ventilation ducts.
G-series Combustible Gas Detectors Technical data
Electrical |
|
Power supply |
16-29 Vdc, reverse-polarity protect.; 18-27 Vac (only for output signal 2-10 Vdc) |
Power consumpt. |
75 mA, max. (1.8 VA for 24 V) |
Analog output signal |
Proportional, overload and short-circuit proof, load < 500 Ohm for current signal, < 50 kOhm for voltage signal 4 - 20 mA or 2 - 10 V = measuring range 3.2 < 4 mA or 1.6 - 2 V = under range > 20- 21.2 mA or 10 - 10.6 V = over range 2 mA or 1 V = fault > 21.8 mA or 10.9 V = fault High |
Sensor performance |
|
Gas type |
See Order Information |
Sensor element |
Pellistor (Catalytic Bead) |
Accuracy |
+/-1% |
Resolution |
0.2% |
Response time t90 |
<15 sec. |
Zero Point variation |
0.5% |
Long-term zero-point drift |
<0.5% LEL |
Long-term sensivity drift |
<1% |
Temp. range |
+20 °C to +50 °C |
Humidity range |
5 to 95% RH non-condensation |
Sensor life time |
> 36 months / normal ambient conditions |
Calibration interval |
6 months |
Poisoning |
|
Pressure range |
Atmospheric ± 20 % |
Storage temp. |
+5 °C to +30 °C |
Storage time |
6 months |
Poisoning |
Sensitivity of pellistor sensor can be influenced by substances containing silicon compounds and even poisoned and destroyed them |
Physical |
|
Housing |
Polycarbonate UL 94 V2 |
Enclosure color |
RAL 7032 (light grey) |
Dimensions |
(W x H x D)94 x 130 x 57 mm |
Protection class |
IP 65 |
Wire connection |
Screw-type terminal min. 0.25 mm2, max. 1.3 mm2 ,3-pin |
Directives |
EMC directives 2014/30/EU CE Compliance with: EN 50271 EN 61010-1:2010 ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 |
Warranty |
12 months (not if sensor is poisoned or overloaded) |
Options |
|
LCD display |
Two lines, 16 characters each, monochrome |
LCD display
Open-collector |
Two lines, 16 characters each, monochrome |
output (2) |
For horn (resettable) and warning lamp |
Switching capacity |
24 Vdc / 50 mA (+ switching) |
Duct Mounting Set |
for sensing gases in duct |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether