CO2 Duct Transmitter with Temperature and Humidity Detection - TG9xx8
• CO2 Measuring range: 0~2000ppm/0~5000ppm optional
• Temperature Measuring range: 0°C~50°C (32°F~122°F) (default)
• Relative humidity Measuring range: 0~100%RH
• Power supply: 24VAC/VDC
• Consumption: 3.5 W max. ; 2.5 W avg.
• Operation temperature: 0~50°C (32~122°F)
• Operation humidity: 0~95%RH, non condensing
• Analog Outputs: 0~10VDC or 4~20mA or 0~5VDC
- Quantity:
- - +
Product Specification
CO2 Duct Transmitter With Temperature and RH% Detection
Model: TG9xx8
• Real time detection carbon dioxide of the air duct
• Detection high accuracy temperature and relative humidity
• Smart sensor probe with extendable probe may be easily installed into any air duct
• With the water-proof and porous film around the sensor probe
• Up to 3xanalog linear outputs for measurements
• Optional Modbus RS485 interface
• With or without LCD display
• CE-approval
TG9xx8 CO2 Duct Transmitter Features
• Designed for real time detecting carbon dioxide, temperature or relative humidity in air ducts.
• NDIR infrared CO2 sensor inside with special Self Calibration and up to 15 years’ lifetime. It makes CO2 measurement more accurate and reliable.
• Combined temperature and humidity digital sensor provide a high accuracy measurement in full range.
• Provide up to 3 analog outputs (0~10VDC or 4~20mA or 0~5VDC) for CO2 temperature and relative humidity.
TG9xx8 CO2 Duct Transmitter Detection Focus
Carbon Dioxide (CO2)
Indoor CO2 level is a universal accepted parameter for the condition of indoor ventilation and air quality. A time period can be preset from 1 to 24 hours, e.g. 5 hours, then the monitor can display CO2 average level during this period, which provides an objective and true data for the measurement of the air quality in a certain space.
• Non-dispersive infrared (NDIR) CO2 sensor with more than 10-year lifetime
• ABC self-calibration technology guarantees reliable CO2 measurement
• CO2 range: 0~2000ppm/0~5000ppm optional
• Rapid response, high stability and consistency
Temperature and humidity
Combined digital temperature and humidity sensor with high accuracy and stability. It also has compensation to CO2 and air quality which makes the measurements more accurate by minimizing environmental effects.
TG9xx8 CO2 Duct Transmitter Typical Applications
• Building management for office areas and residental
• Ventilation control system
TG9xx8 CO2 Duct Transmitter Specifications
Monitoring parameters |
CO2 |
Temperature |
Relative humidity |
Sensing element |
Non-Dispersive Infrared Detector
(NDIR) |
Digital combined temperature and humidity sensor |
|
Measuring range |
0~2000ppm(default)
0~5000ppm
(selectable in the order)
|
0°C~50°C (32°F~122°F)
(default) |
0~100%RH |
Display Resolution |
1ppm |
0.1°C |
0.1%RH |
Accuracy@25°C (77°F) |
±60ppm + 3% of reading |
±0.5°C (0°C~50°C) |
±3%RH (20%-80%RH) |
Life time |
15 years (normal) |
10 years |
|
Calibration cycle |
ABC Logic Self
Calibration |
- | - |
Response Time |
<2 minutes for 90% change |
<10 seconds to reach 63% |
|
Warm up time |
2 hours (first time) 2 minutes (operation) |
||
Electrical Characteristics |
|||
Power supply |
24VAC/VDC |
||
Consumption |
3.5 W max. ; 2.5 W avg. |
||
Outputs |
Two or three analog outputs 0~10VDC(default) or 4~20mA (selectable by jumpers) 0~5VDC (selected at place the order) |
||
Modbus RS485 interface (optional) |
RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address |
||
Conditions of Using and Installation |
|||
Operation conditions |
0~50°C (32~122°F); 0~95%RH, non condensing |
||
Storage conditions |
0~50°C (32~122°F) / 5~80%RH |
||
Weight |
320g |
||
Installation |
Fixed on the air duct with 100mm installation hole size |
||
IP class of the housing |
IP50 for no LCD IP40 for with LCD |
||
Standard |
CE-Approval |
TG9XX8 CO2 Duct Transmitter Models Information
TG9X1 X2 8 L-Y02/05 E-Tab
X1:
analog output
3- 3Xanalog outputs for CO2 + Temperature + Humidity
1- 1xanalog output for CO2
0- no analog output
X2:
Modbus interface
1- with Modbus interface
0- no Modbus interface
8:
CO2 sensor code
L:
LCD display
Non-required option. No L indicates no LCD
Y:
default output type
A- 4~20mA
V- 0~10VDC (default)
V5- 0~5VDC (can’t be changed to another output by jumpers)
02/05:
CO2 measurement range
02- 0~2000ppm (default)
05- 0~5000ppm
E:
extended duct probe up to 209mm
Non-required option. No E indicates the standard probe length of 139mm
Tab:
temperature scaling
T05: 0°C~50°C (32°F~122°F) (default)
T06: 0°C~60°C (32°F~140°F)
No this item indicates no output for temperature measurement.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether