Combustible Gas Pellistor - CH-A3
• Detection range: 0-100% LEL methane
• Sensitivity: 15~21mV / % methane
• Response time: 15s
• Zero: ± 20mV in zero air
• Linearity: 6% methane when 5% non-linear
• Voltage: 3.0V (±0.2 V)
• Power consumption: 190mW
• Weight: < 26 g
• Operating life: > 24months
- Quantity:
- - +
Product Specification
CH-A3 Combustible Gas Pellistor Description
Alphasense flammable gas pellistors are available in two housing sizes: A for fixed installation applications and A or D for portable applications.
The innovative design of the Alphasense pellistor range provides high quality, low power (only 190mW) and excellent poison resistance. All pellistors are housed in certified flameproof chambers.
CH-A3 is a drop-in (20mm diameter) replacement to existing products with improved stability and poison resistance.
CH-A3 Combustible Gas Pellistor PERFORMANCE
Sensitivity
mV / % methane
15 to 22
Response time
t90 from air to 50% LEL methane (s)
< 15 (typically < 7)
Zero
mV in zero air
±20
Range
% LEL methane
0 to 100
Linearity
% methane when 5% non-linear
6
CH-A3 Combustible Gas Pellistor ENVIRONMENTAL
Sensitivity @ -20°C
% sensitivity change, referenced to 20°C
< 100.5 to 105.5
Sensitivity @ 50°C
% sensitivity change, referenced to 20°C
< 100 to 103
Zero @ -20°C
% LEL change, referenced to 20°C
< +0.5 to -2
Zero @ 50°C
% LEL change, referenced to 20°C
< 0 to -1.5
Temperature Range
Certification to T4
-40 to +55°C
Humidity
12% sensitivity loss from 0% to 80 % rh (22°C)
Typical zero increase % LEL from 0 to 80 %rh (22°C)
1.0
Pressure
Sensitivity change from 0 to 75 kPa (gauge)
< 3%
CH-A3 Combustible Gas Pellistor INHIBITION/POISONING
Chlorine
12hrs 20ppm Cl2, 50 % sensitivity loss, 2 day recovery
< 10% loss
Hydrogen Sulfide
12hrs 40ppm H2S, 50 % sensitivity loss, 2 day recovery
< 50% loss
HMDS
hrs until 50% activity loss @ 10ppm HMDS
9
Optional H2S disposable filter can be ordered. Part no. ASF-1
CH-A3 Combustible Gas Pellistor ELECTRICAL
Voltage
V (±0.2 V)
3.0
Power consumption
mW
190
Voltage sensitivity
% sensitivity change / 0.1V change
3
CH-A3 Combustible Gas Pellistor KEY SPECIFICATIONS
Weight
g
< 26
Operating life
months until 75% original sensitivity (24 month warranted)
> 24
Sensitivity
Hydrocarbon/Gas |
% Sensitivity
relative to Methane |
% LEL Sensitivity
to Methane |
Hydrogen |
130 to 140 |
160 to 175 |
Propane |
150 to 190 |
350 to 450 |
Butane |
150 to 180 |
420 to 500 |
n-Pentane |
180 to 200 |
600 to 670 |
Nonane |
150 to 170 |
800 to 950 |
Carbon Monoxide |
42 to 44 |
17 to 18 |
Acetylene |
150 to 170 |
300 to 340 |
Ethylene |
150 to 170 |
270 to 320 |
Isobutylene |
180 to 200 |
450 to 500 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Smoke Sensor Flammable Gas Sensor
-
Miniature Size Combustible Gas Pellistor
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Higher Temperature Resistivity Flammable Gas Sensors
-
Flammable Gas Sensors Used for Gas Setectors and Leak Testers
-
Higher Temperature Resistivity Flammable Gas Sensors
-
Miniature & Low Power Consumption Type Flammable Gas Sensor