Carbon Dioxide Transmitter with Temperature and RH% Option - G01-CO2-B10C/30C
• CO2 range: 0~2000ppm/ 0~5,000ppm optional
• CO2 Accuracy: ±40ppm + 3% of reading or ±75ppm
• Temperature dependence: 0.2% FS per °C
• Stability: <2% of FS over life of sensor
• Power supply: 24VAC/VDC
• Consumption: 1.8 W max. ; 1.2 W avg.
• Operation temperature: 0~50°C (32~122°F)
• Operation humidity: 0~95%RH, non condensing
- Quantity:
- - +
Product Specification
Carbon Dioxide Transmitter
with Temperature and RH% Option
Model#: G01-CO2-B10C/30C
• Real time carbon dioxide detection and transmitting
• High accuracy Temperature and humidity detection
• NDIR infrared CO2 sensor with patented self calibration
• Provide 3xanalog linear outputs for measurements
• Optional LCD display of all measurements
• Modbus communication
• CE-approval
G01-CO2-B10C/30C Carbon Dioxide Transmitter Features
• Design for real time measuring ambiance carbon dioxide level and temperature +RH%
• NDIR infrared CO2 sensor inside with special Self Calibration. It makes CO2 measurement more accurate and more reliable.
• More than 10 years lifetime of CO2 sensor
• High accuracy temperature and humidity measurement
• Combined both humidity and temperature sensors seamlessly with the digital auto compensation
• Provide up to three analog linear outputs for measurements
• LCD is optional to display CO2 and temperature &RH measurements
• Optional Modbus communication
• 24VAC/VDC power supply
• EU standard and CE-approval
G01-CO2-B10C/30C Carbon Dioxide Transmitter Application
• Building ventilation systems
• Industry ventilation systems
• Airport, train station, shopping mall, office, classroom and other public places for air quality measurement and indication
• Lab., warehouse, and other places to detect CO2+Temp. +RH%
G01-CO2-B10C/30C Carbon Dioxide Transmitter Specifications
CO2 Measurement | ||
Sensing element |
Non-Dispersive Infrared Detector (NDIR) |
|
CO2 range |
0~2000ppm/ 0~5,000ppm optional | |
CO2 Accuracy @22°C(72°F) |
±40ppm + 3% of reading or ±75ppm (whichever is greater) |
|
Temperature dependence |
0.2% FS per °C |
|
Stability |
<2% of FS over life of sensor (15 year typical) |
|
Pressure dependence |
0.13% of reading per mm Hg |
|
Calibration |
ABC Logic Self Calibration Algorithm |
|
Response time |
<2 minutes for 90% step change typical |
|
Signal update |
Every 2 seconds |
|
Warm-up time |
2 hours (first time) / 2 minutes (operation) |
|
|
Temperature |
Humidity |
Measuring range |
0°C~50°C(32°F~122°F) (default) |
0 -100%RH |
Accuracy |
±0.4°C (20°C~40°C) |
±3%RH (20%-80%RH) |
Display resolution |
0.1°C |
0.1%RH |
Stability |
<0.04°C/year |
<0.5%RH/year |
General Data |
||
Power supply |
24VAC/VDC |
|
Consumption |
1.8 W max. ; 1.2 W avg. |
|
Analog outputs |
1~3 X analog outputs 0~10VDC(default) or 4~20mA (selectable by jumpers) 0~5VDC (selected at placing the order) |
|
Modbus communication (optional) |
RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address |
|
Operation conditions |
0~50°C (32~122°F); 0~95%RH, non condensing |
|
Storage conditions |
10~50°C (50~122°F), 20~60%RH non condensing |
|
Net Weight |
240g |
|
Dimensions |
130mm(H) x 85mm(W) x 36.5mm(D) |
|
Installation |
wall mounting with 65mm x 65mm or 2" x 4" wire box |
|
Housing and IP class |
PC/ABS fireproof plastic material, protection class: IP30 |
|
Standard |
CE-Approval |
G01-CO2-B10C/30C Carbon Dioxide Transmitter Models Guide
G01-CO2-B X 0 C - Y 0 Z - U 02/05 - T/TH - Txx
X:
LCD or no LCD
1- Without LCD, 24VAC/VDC power supply
3- LCD display, 24VAC/VDC power supply
C:
24VAC/VDC power supply
Y:
analog output quantity
3- 3Xanalog outputs (for CO2, temperature, humidity)
2- 2Xanalog outputs (for CO2, temperature)
1- 1xanalog output (for CO2)
0- no analog output
Z:
Modbus communication
1- with Modbus communication
0- no Modbus
U:
type of analog output
V- 0~10VDC (default)
A- 4~20mA
V5- 0~5VDC (not be changed)
02/05:
CO2 range
02- 0~2000ppm
05- 0~5000ppm
T/TH:
temperature option/ temperature and humidity option
Txx:
temperature scaling
T05: 0°C~50°C(32°F~122°F) default (without the postfix indicates the default)
T06: 0°C~60°C(32°F~140°F)
T26: -20°C~60°C(-4°F~140°F)
Accessory (selectable at placing the order)
921: back plate for wall mounting
921+922: desktop bracket
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether