Carbon Dioxide Controller for Greenhouse Application - F2000IAQ-CO2-3003D/5003D

  • Carbon Dioxide Controller for Greenhouse Application
  • Carbon Dioxide Controller for Greenhouse Application
Mouse over image to zoom

​• Gas detected: Carbon Dioxide (CO2)
​• Response Time: <2 minutes for 90% step change
​• CO2 measuring range: 0~5,000ppm, 0~20,000ppm (optional)
​• Temperature measuring range: -20~60°C(-4~140°F)
​• Humidity measuring range: 0~99%RH
​• Output resolution: 10Bit
• Operation temperature: 0~50°C(32~122°F)
​• Operation humidity​: 0~95%RH, non condensing​

  • Model Number: F2000IAQ-CO2-3003D/5003D
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

CO2 Controller for Greenhouse or Similar Application
Model: F2000IAQ-CO2-3003D
CO2 + Temperature + Humidity Controller with the local Programmable Control


F2000IAQ-CO2-3003D Carbon Dioxide Controller Features
• Especially designed for agriculture equipments such as greenhouses, food and vegetable storages.  Real-time detecting CO2 level, temperature  and  humidity  with  the  local programmable control.
• Wall mounting, LCD display
• Carbon dioxide sensor, temperature sensor and humidity sensor are internal. The three values can be apart set.
• Non-Dispersive Infrared Detector (NDIR) CO2 sensor, more than 10 years lifetime
• CO2 range: 0~5000ppm / 0~20000ppm / 0~50000ppm
• Special ABC Logic with patented Self Calibration Algorithm makes the CO2 sensor used up to more than 10 years
• Temperature setting range: 5~45°C 
   Humidity setting range: 5~95%RH
• Provid three relays outputs to control a CO2 generator, a  temperature device and a humidity devise or a ventilator.
• Special photosensitive sensor detection can make the working mode of the CO2 generator changeover automatically in day and night.
• Provide brightness adjustment range to make day/night limit setting by end users.
• RS-485 communication interface with 15KV antistatic protection makes the controller being connected with PC (option)
• Multiple functions, high performance, low price, make it praiseworthily.


F2000IAQ-CO2-3003D Carbon Dioxide Controller Application
F2000IAQ-CO2-3003D multiple controller is used to control CO2 level, temperature and humidity in order to offer right environment for plants growth or for foods storage.


It provides three dry contact outputs to control a carbon dioxide generator and a ventilator or other temperature/humidity equipments. It can provide RS485 communication with independent address to PC or other control systems.


It will be used below application:
1. Greenhouses, which include vegetable planting houses and flowers planting houses.
2. Modern hydroponics gardens
3. Other relevant field of agriculture
4. Keep food and vegetable on fresh


F2000IAQ-CO2-3003D Carbon Dioxide Controller Specifications

Gas detected
Carbon Dioxide (CO2)
Sensing element
Non-Dispersive Infrared Detector (NDIR) with more than 10 years lifetime
Temperature sensor
NTC
Humidity sensor 
HS series capacitive sensor
Temperature dependence
0.2% FS/°C
Temperature correction
Self compensation
Power supply
100VAC~240VAC or 24VAC, 50/60HZ±10%, selectable in order
Consumption
3.5 W max. ; 2.5 W avg.
Accuracy@25°C(77°F)
±40ppm + 3% of reading (0~5,000ppm)
±75ppm or 10% reading whichever is greater (0~20,000ppm)
Stability
<2% of FS over life of sensor (15 yr typical)
Calibration interval
ABC Logic Self Calibration Algorithm
Non linearity
<1% of FS
Pressure dependence
0.13% of reading per mm Hg
Altitude calibration
Programmable from 0-9,900m in 100m increments
Response Time
<2 minutes for 90% step change
Signal update
Every 2 seconds
Warm up time
24 hours (first time)
10 minutes (operation)
CO2 measuring range
0~5,000ppm
0~20,000ppm (optional)
CO2 setting & Display resolution
1ppm
Temperature measuring range
-20~60°C(-4~140°F)
Temperature setting range
5~45°C(41~113°F)
Humidity measuring range
0~99%RH
Humidity setting range
5~95%RH
Output resolution
10Bit
Relay output
Three ways dry contact outputs with programmable selection to control
CO2, temperature, humidity
Rated switching current: 2A(220VAC/30VDC), resistance load
Communication interface
RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable
selection), 15KV antistatic protection, 3 independent base address, max
network node 64.
Flow rates
80 ~ 120 cc/min
Operation conditions
0~50°C(32~122°F); 0~95%RH, non condensing
Storage conditions
0~50°C(32~122°F); 0~90%RH
Weight
360g
Dimensions
130mm x 90mm x 40mm
Installment standard
65mm x 65mm or 2" x 4" wire box
Wiring standard
Wire section area <1.5mm2
Approval Standard
CE-Approval


F2000IAQ-CO2-3003D Carbon Dioxide Controller Models

Model
Description
F2000IAQ-CO2-3003D-(D)/(C)
CO2& temperature& humidity detection to control CO2 generator and
ventilation, photosensitive sensor detection to control CO2 generator day/night
working mode. Power supply: (D): 100~240VAC  (C): 24VAC
F2000IAQ-CO2-5003D-(D)(C)
CO2&temperature&humidity detection to control CO2 generator and
temperature & humidity devices, photosensitive sensor detection to control
CO2 generator day/night working mode. RS485 communication interface.
Power supply: (D): 100~240VAC  (C): 24VAC