Carbon Dioxide (CO2) Duct Probe Transmitter - TG9xx6x
• Measurement Range: 0~2,000ppm/0~5,000ppm/0~50,000ppm
• Accuracy: ±40ppm + 3% of reading @22°C(72°F)
• Stability: <2% of full scale over the life of the sensor
• Non-linearity: <1% of full scale @22°C(72°F)
• Power supply: 24VAC/24VDC
• Consumption: 1.8 W max. ; 1.0 W avg.
• Operation temperature: 0°C~50°C (32~122°F)
• Operation humidity: 0~100%RH
- Quantity:
- - +
Product Specification
Carbon Dioxide Duct Probe Transmitter
TG9xx6x
• The TG9 is a CO2 transmitter designed for detection carbon dioxide in air ducts of HVAC systems.
• The CO2 sensor uses the Non-Dispersive Infrared Technology (NDIR) with the patented self-calibration system to guarantee the long term stability and up to 15 years life time.
• Optional temperature and humidity detection with a high accuracy digital combined sensor, it provides a digital interface and outstanding full range linearity.
• T he one or three analog 0-10V or 4~20mA outputs are selectable by jumpers.
• Modbus RS485 communication interface option.
• With or without LCD
• Smart and skillful design for structure, with a special demountable and replaceable filter to avoid pollution and influence of measurement.
• Provide a split type model with an external sensor probe, 2 meter connection cable, is used in incubators or food stores etc.
TG9xx6x Carbon Dioxide Duct Probe Transmitter Features
• Special used to real-time detect CO2 concentration in air ducts.
• NDIR infrared CO2 sensor inside with Self-Calibration and up to 15 years lifetime
• Humidity and temperature detection optional
• Digital combined temperature and humidity sensor provide the highest accuracy in full range
• White backlit LCD display option can display CO2 measurement as well as temperature and RH measurements
• Providing one or three 0~10VDC or 4~20mA analog outputs
• Modbus RS485 communication interface optional
• Smart structure and attractive housing provides you a unique operation feeling
• Simple and skillful design and installation with a demountable and replaceable filter to provides dust-proof protection
• Special a 180° rotatable fastness position for the probe can change the direction of air detection.
• Provides a split type with an external sensor probe for some special applications
• All housing and probe are IP54 class
• CE-Approval
TG9xx6x Carbon Dioxide Duct Probe Transmitter Typical Applications
• HVAC systems of all commercial buildings and residential houses
• Ventilation control system
• Plant factories, greenhouses
• Food stores, incubators
• Other places where needs real time detection and control CO2 concentration
TG9xx6x Carbon Dioxide Duct Probe Transmitter Specifications
CO2 Sensor |
Non-Dispersive Infrared Detector (NDIR) |
|
Measurement Range |
0~2,000ppm / 0~5,000ppm / 0~50,000ppm (selectable in the order) |
|
Accuracy |
±40ppm + 3% of reading @22°C(72°F) |
|
Stability |
<2% of full scale over the life of the sensor |
|
Calibration |
Self-calibration system |
|
Response Time |
<5 minutes for 90% step change at low duct speed |
|
Non-linearity |
<1% of full scale @22°C(72°F) |
|
Duct Air Velocity |
0~450m/min |
|
Pressure Dependence |
0.135% of reading per mm Hg |
|
Temperature Dependence |
0.2% of full scale per ºC |
|
Warm up time |
24 hours (first time) 10 minutes (operation) |
|
Temperature & Humidity Sensor |
Temperature |
Relative Humidity |
Sensing element: |
Band-gap-senor |
Capacitive humidity sensor |
Measuring range |
-20°C~60°C (default) 0~60°C selectable in order |
0 -100%RH |
Accuracy |
±0.4°C (0°C~50°C) |
±3%RH (20%-80%RH) |
Display resolution |
0.1°C |
0.1%RH |
Stability |
±0.1°C per year |
±1%RH per year |
General Data |
|
|
Power supply |
24VAC/24VDC |
|
Consumption |
1.8 W max. ; 1.0 W avg. |
|
LCD display |
White backlit LCD display CO2 measurement or CO2 + temperature& humidity measurements |
|
Analog output |
1x 0~10VDC or 4~20mA output for CO2 3x 0~10VDC or 4~20mA outputs for CO2+ Temperature +RH The voltage output or current output can be selectable by jumpers |
|
Modbus RS485 Interface |
19200bps, 15KV antistatic protection. |
|
Operation conditions |
0°C~50°C (32~122°F); 0~100%RH |
|
Storage conditions |
0~50°C (32~122°F) / 5~95%RH |
|
Net weight |
320g |
|
IP class |
IP50 for models without LCD; IP40 for models with LCD |
|
Standard Approva |
CE-Approval |
TG9xx6x Carbon Dioxide Duct Probe Transmitter Models Information
Model Name
Description
CO2 Duct Probe Transmitter
without LCD
TG9106-02/05/20
1Xanalog output for CO2 measurement.
-02: CO2 range 0~2000ppm
-05: CO2 range 0~5000ppm
-20: CO2 range 0~20,000ppm
TG9116-02/05/20
1X analog output for CO2 measurement.
Modbus RS485 interface
TG9316-02/05/20
3Xanalog outputs for CO2 measurement, and temperature & humidity
Modbus RS485 interface
CO2 Duct ProbeTransmitter
with LCD
TG9116L-02/05/20
1Xanalog output for CO2 measurement. LCD display CO2
Modbus RS485 interface
TG9316L-02/05/20
3Xanalog outputs for CO2 measurement, and temperature & humidity
LCD display CO2and temperature & humidity
Modbus RS485 interface
Split CO2 Sensor
Probe
TG5106
1X analog output for CO2 measurement. External CO2 sensor probe
with 2m cable. CO2 range: 0~50,000ppm
TG5016
Modbus RS485 interface. CO2 range: 0~50,000ppm
External CO2 sensor probe with 2m cable.
TG5116
1Xanalog output for CO2 measurement. Modbus RS485 interface.
External CO2 sensor probe with 2m cable. CO2 range: 0~50,000ppm
TG5016-TH
CO2+temperature&RH detection. Modbus RS485 interface.
CO2 range: 0~50,000ppm
External CO2 sensor probe with 2m cable.
TG5116L
LCD display CO2 measurement. 1Xanalog output.
Modbus RS485 interface.
External CO2 sensor probe with 2m cable. CO2 range: 0~50,000ppm
TG5016L-TH
Display CO2+temperature&RH. Modbus RS485 interface.
CO2 range: 0~50,000ppm
External CO2 sensor probe with 2m cable.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether