• Measurement Range: 0~2000ppm (default), 0~5000ppm selectable
• Accuracy: ±60ppm + 3% of reading @22°C(72°F)
• Stability: <2% of full scale over the life of the sensor
• Response Time: <5 minutes for 90% step change at low duct speed
• Non-linearity: <1% of full scale @22°C(72°F)
• Power supply: 24VAC/24VDC ± 5%
• Operation temperature: 0°C~50°C (32~122°F)
• Operation humidity: 0~99%RH, non condensing
- Quantity:
- - +
Product Specification
TGP SERIES
Carbon Dioxide Detector/Transmitter
TGP Series Carbon Dioxide Detector/Transmitter Features
• Real-time detect CO2 level of indoor environment
• NDIR infrared CO2 sensor with Self-Calibration and up to 15 years lifetime
• Humidity and temperature detection optional
• Combined temperature and humidity sensor provide the highest accuracy in full range
• Wall mounting with the external sensor probe with the higher accuracy of measurements
• Backlit LCD display option can display CO2 measurement and temperature+ RH measurements
• Providing one or three 0~10VDC or 4~20mA or 0~5VDC analog outputs
• Modbus RS485 communication interface makes usage and test more convenient
• Smart structure with the simple installation and wiring
• CE-Approval
TGP Series Carbon Dioxide Detector/Transmitter Typical Applications
• HVAC systems
• In BAS to detect the CO2 level and the data transmittance
• Ventilation control system
TGP Series Carbon Dioxide Detector/Transmitter Specifications
CO2 Sensor |
Non-Dispersive Infrared Detector (NDIR) |
|
Measurement Range |
0~2000ppm (default) 0~5000ppm selectable |
|
Accuracy |
±60ppm + 3% of reading @22°C(72°F) |
|
Stability |
<2% of full scale over the life of the sensor |
|
Calibration |
Self-calibration system |
|
Response Time |
<5 minutes for 90% step change at low duct speed |
|
Non-linearity |
<1% of full scale @22°C(72°F) |
|
Pressure Dependence |
0.135% of reading per mm Hg |
|
Temperature Dependence |
0.2% of full scale per °C |
|
Temperature & Humidity Sensor |
Temperature |
Relative Humidity |
Sensing element |
Band-gap-sensor |
Capacitive humidity sensor |
Measuring range |
0°C~50°C (32°F~122°F) (default) |
0 ~100%RH |
Accuracy |
±0.5°C (0°C~50°C) |
±3%RH (20%-80%RH) |
Display resolution |
0.1°C |
0.1%RH |
Stability |
±0.1°C per year |
±1%RH per year |
General Data |
|
|
Power supply |
24VAC/24VDC ± 5% |
|
Consumption |
1.8 W max. ; 1.0 W avg. |
|
LCD display |
White backlit LCD display CO2 measurement or CO2 + temperature& humidity measurements |
|
Analog output |
1 or 3 X analog outputs 0~10VDC (default) or 4~20mA (selectable by jumpers) 0~5VDC (selected at place the order) |
|
Modbus RS485 Interface |
19200bps, 15KV antistatic protection. |
|
Operation conditions |
0°C~50°C (32~122°F); 0~99%RH, non condensing |
|
Storage conditions |
0~60°C (32~140°F) / 5~95%RH |
|
Net weight |
300g |
|
IP class |
IP50 |
|
Standard Approval |
CE-Approval |
TGP Series Carbon Dioxide Detector/Transmitter Models Information
Model Name |
Model No. |
Description |
CO2 Transmitter (without LCD) |
TGP108 |
1X linear analog output for CO2 measurement |
TGP118 |
1X linear analog output for CO 2 measurement Modbus RS485 interface |
|
TGP318 |
3X linear analog outputs for CO2 measurement, temperature & humidity. Modbus RS485 interface |
|
TGP018 |
CO2 and temperature & humidity detection, with a Modbus RS485 interface |
|
CO2 Transmitter (with LCD) |
TGP118L |
1X linear analog output for CO2 measurement Modbus RS485 interface LCD display CO2 |
TGP318L |
3X linear analog outputs for CO2 measurement, temperature & humidity. Modbus RS485 interface LCD display CO2 and temperature & humidity |
|
TGP018L |
CO2 and temperature & humidity detection and LCD display. Modbus RS485 interface. |
Postfix description
T05: 0°C~50°C (32°F~122°F) default (without the postfix indicates the default)
TGP1XX - Y - 02/05
TGP3XX - Y - 02/05 - Txx
Y:
type of output signal
V- 0~10VDC (default)
A- 4~20mA
V5- 0~5VDC (not be changed)
02/05:
CO2 range
02- 0~2000ppm
05- 0~5000ppm
Txx:
temperature scaling
T06: 0°C~60°C (32°F~140°F)
T26: -20°C~60°C (-4°F~140°F)
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether