AXCA Series ASCX Compatible Amplified Pressure Sensors - 15 PSI-A-4V-ASCX
• Supply Voltage: +4.5 to +5.5 Vdc
• Lead Soldering Temperature (2-4 sec.): 250 °C
• Quiescent Current: 7.5 mA
• Compensated Temperature: 0 to 70°C
• Operating Temperature: -25 to 105°C
• Storage Temperature: -55 to 125°C
• Humidity Limits (non condensing): 0 to 95% RH
- Quantity:
- - +
Product Specification
ASCX Series Compatible Pressure Sensors
Compatible to Sensym ASCX Series
ASCX Series Compatible Pressure Sensors General Description
The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides a ratiometric 4.5-volt output span with superior output characteristics. The sensor housing has been designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is intended for use with noncorrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
ASCX Series Compatible Pressure Sensors Features
• 5 Vdc Supply
• High Level Voltage Output
• Ratiometric 4.5 V Span
• Temperature Compensated
• Calibrated Zero and Span
• MULTIPLE Pressure Ranges
ASCX Series Compatible Pressure Sensors Applications
• Medical Instrumentation
• Environmental Instrumentation
• HVAC Instrumentation
• Pneumatic Controls
AXCA Series ASCX Compatible Pressure Sensors
Maximum Ratings |
|
Environmental Specifications |
||
Supply Voltage, Vs |
+4.5 to +5.5 Vdc |
Compensated Temperature |
0 to 70°C |
|
Lead Soldering Temperature (2-4 sec.) |
250 °C |
Operating Temperature |
-25 to 105°C |
|
Quiescent Current |
7.5 mA |
Storage Temperature |
-55 to 125°C |
|
|
|
Humidity Limits (non condensing) |
0 to 95% RH |
ASCX Series Compatible Pressure Sensors Pressure Ranges
Part Number |
Operating Pressure |
Proof Pressure |
Burst Pressure |
1 PSI-D-4V-ASCX |
0 - 1 PSID |
5 PSI |
10 PSI |
5 PSI-D-4V-ASCX |
0 - 5 PSID |
15 PSI |
30 PSI |
15 PSI-D-4V-ASCX |
0 - 15 PSID |
45 PSI |
75 PSI |
15 PSI-A-4V-ASCX |
0 - 15 PSIA |
45 PSI |
75 PSI |
30 PSI-D-4V-ASCX |
0 - 30 PSID |
100 PSI |
150 PSI |
30 PSI-A-4V-ASCX |
0 - 30 PSIA |
100 PSI |
150 PSI |
100 PSI-D-4V-ASCX |
0 - 100 PSID |
150 PSI |
150 PSI |
100 PSI-A-4V-ASCX |
0 - 100 PSIA |
150 PSI |
150 PSI |
Performance Characteristics for 1/5 PSI-D-4V-ASCX
Parameter |
Minimum |
Nominal |
Maximum |
Units |
Output Span |
4.43 |
4.50 | 4.57 |
Volt |
Span Shift (0 °C to 70 °C) |
- |
±0.2 |
±1.5 |
%Span |
Offset Voltage @ zero pressure |
0.18 |
0.25 |
0.32 |
Volt |
Offset Shift (0 °C to 70 °C) |
- |
±0.5 |
±1.5 |
%Span |
Combined Linearity and Hysteresis Error |
- |
±0.1 |
±0.5 |
%Span |
Repeatability |
- |
±0.2 |
±0.5 |
%Span |
Response Time |
- |
100 |
- |
uSec |
Performance Characteristics for 15/30/100 PSI-x-4V-ASCX
Parameter |
Minimum |
Nominal |
Maximum |
Units |
Output Span |
4.45 |
4.50 |
4.55 |
Volt |
Span Shift (0 °C to 70 °C) |
- |
±0.2 |
±1.0 |
%Span |
Offset Voltage @ zero pressure |
0.20 |
0.25 |
0.30 |
Volt |
Offset Shift (0 °C to 70 °C) |
- |
±0.5 |
±1.0 |
%Span |
Combined Linearity and Hysteresis Error |
- |
±0.1 |
±0.5 |
%Span |
Repeatability |
- |
±0.2 |
±0.5 |
%Span |
Response Time |
- |
100 |
- |
uSec |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃