“All-in-ONE” Hand-held Temperature and Humidity Measuring Device - XA1000

  • “All-in-ONE” Hand-held Temperature and Humidity Measuring Device
Mouse over image to zoom

Measuring range (full accuracy): 800...1,100mbar
Accuracy at 25°C,1013.25mbar: 0.5mbar
Long-term stability: typ. - 1mbar/year
Measurement resolution: 0.024mbar
Measuring principle: Piezoresistive

  • Model Number: XA1000
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

- TFT colour display, legible in sunlight
- Capacitive touch operation
- Sampling rate 1s
- Data recording of up to 3 channels in parallel
- Graphical analysis with standard deviatzion resolution
- Integrated Flash memory for 200 recording blocks with maximum length of 3 hours
- USB port for data transfer to SmartGraph3 (included in delivery)
- Various languages selectable
- Measuring temperature, humidity, air ow via external digital sensors
- Integrated air pressure measurement
- Numerous calculated measurements
- Online  rmware update


The most precice and  exible all-rounder instrument for professional applications-easy to handle and robust. Allows various intelligent sensors to be connected with automatic recognition, saves measuring campaignes, allows all climate data to be calculated and archieved on a computer for further evaluation by SmartGraph3 software.


Hand-held Measuring Device XA1000 “All-in-ONE” 
“All-rounder” in the measurement technology segment. A universal measuring device for professionals with the inclusion of exchangeable SDI Sensors. Highly precise measurements of temperature and relative humidity. Integrated air pressure sensor, online/offl ine data recording. Equipment test certifi cate, can be calibrated.


Technical data Dimensions 170 x 62 x 34 mm
Weight ca. 205g
Storage conditions Permitted ambient temperature -20...60°C
Permitted rel. humidity <90% RH non-condensing
Operating conditions Permitted rel. humidity <90% RH (20g/m3) non-condensing
Permitted altitude above sea level 4000m
Power supply Power supply 4 Alkaline LR6 AA 1.5V / USB 5V
Active power consumption Approx. 400mW
Battery life passive Approx. 1 year
Battery life active Min. 24 hours
Sensor power supply 5.5V ± 10% DC, max. 200mA
Data storage Integrated data storage Up to 200 gauges taking approx. 1 mill.values
Interface USB Cable and SmartGraph3 software included
Resolution Denition of measured values 2 decimal places
Display
Control
Touch screen, capacitive
Technology
TFT, resolution 240x320, 65k colours, very good contrast due to Piezoresistive technology
Surface, toughened glass
Degree of hardness: 7, scratch-resistant
Integrated air pressure sensor Measuring range (full accuracy) 800...1,100mbar
Accuracy at 25°C,1013.25mbar 0.5mbar
Long-term stability typ. - 1mbar/year
Measurement resolution 0.024mbar
Measuring principle Piezoresistive
Calculated measurement categories for external temperature/humidity sensors
Mathematical: MIN/MAX/AVG/HOLD
Temperature (°C/°F)
Rel. humidity (% RH)
Rel. humidity of ice (% RH)
Water vapour density (absolute humidity) g/m3
Dew point temperature °C/°F
Frost point temperature °C/°F
Mixing ratio at saturation (100%) g/kg
Volume fraction of water vapour /mass fraction of water vapour (%)
Wet-bulb temperature °C/°F
Ice-bulb temperature °C/°F
Speci c Enthalpy (mass of air) kJ/kg
Saturation vapour pressure above ice/water (hPa) 
Vapour particle pressure (hPa)
Air density kg/m3
Calculated measurement categories for external airfl ow sensors
Operating air ow volume - various units: (m3 /s) (m3 /h) (l/min) 
Standard air ow volume: DIN 1343 (°C, 1013.25hPa), ISO 2533 (15°C, 1013.25hPa), DIN 1945 (20°C, 1013.25hPa)
Various units: (m3 /s), (m3 /min), (m3 /h), (I/min)
Compatibility
Sensor/probe: all SDI/digital sensors (temperature, humidity, SDI air ow, air pressure integrated) 
Accessories
Extension and/or connecting cable for digital sensor, 2m Extension and/or connecting cable for digital sensor, 10m

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service