ADO Series Digital Output Pressure Sensors - 5 INCH-D-DO/1 PSI-D-DO
• Supply Voltage (Vcc): 7Vdc
• Common-mode pressur: 50 psig
• Lead Temperature (soldering 2-4 sec.): 250°C
• Operating Voltage: +4.75 to +5.25Vdc
• Operating Temperature: -25 to +90° C
• Operating Temperature: -25 to +90° C
• Humidity Limits: 0 to 95% RH (non condensing)
• Resolution: 12 Bit
- Quantity:
- - +
Product Specification
Digital Output Pressure Sensors
Enhanced Digital Output Sensors
ADO Series Digital Output Pressure Sensors General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and MICROWIRE/PLUS® compatible as well as fully compatible with the All Sensors GA142 Series sensors.
In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level, asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and conversion factor. The command set also allows the host to select a high resolution output mode, make minor adjustments to offset and has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals are 5V TTL/CMOS compatible.
ADO Series Digital Output Pressure Sensors Features
• 5" H2O to 100psi Pressure Ranges
• All Combined Errors Over Temperature Less Than 0.1%, Typical
• Wide -20 to 85°C Compensated Temperature Range
• Electrically Compatible to All Sensors GA142 Series
• Enhanced Dual Serial Interface Mode
ADO Series Digital Output Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
• Meteorology
ADO Series Digital Output Pressure Sensors
Absolute Maximum Ratings |
|
Environmental Specifications |
||
Supply Voltage (Vcc) |
7Vdc |
Operating Voltage |
+4.75Vdc to +5.25Vdc |
|
Voltage on Any Pin with Respect to Gnd |
-0.6 to Vcc+0.6V |
Compensated Temperature |
-20 to +85 °C |
|
Common-mode pressure |
50 psig |
Operating Temperature |
-25 to +90 °C |
|
Lead Temperature (soldering 2-4 sec.) |
250°C |
Storage Temperature |
-40 to 125 °C |
|
|
|
Humidity Limits |
0 to 95% RH (non condensing) |
ADO Series Digital Output Pressure Sensors Standard Pressure Ranges
Part Numbe |
Operating Pressure |
Units |
FSO |
Digital Span |
Proof Pressure |
Burst Pressure |
5 INCH-D-DO |
-5 to 5 |
inH2O |
5 |
1 |
200 inH2O |
300 inH2O |
10 INCH-D-DO |
-10 to 10 |
inH2O |
10 | 1 |
200 inH2O |
300 inH2O |
1 PSI-D-DO |
-1 to 1 |
PSI |
1 | 1 |
200 inH2O |
300 inH2O |
5 PSI-D-DO |
-5 to 5 |
PSI |
5 |
1 |
10 PSI |
30 PSI |
15 PSI-D-DO |
-15 to 15 |
PSI |
15 |
1 |
60 PSI |
120 PSI |
15 PSI-A-DO |
0 to 15 |
PSIA |
15 |
2 |
60 PSI |
120 PSI |
30 PSI-D-DO |
-30 to 30 |
PSI |
30 | 2 |
90 PSI |
150 PSI |
30 PSI-A-DO |
0 to 30 |
PSIA | 30 | 2 |
90 PSI |
150 PSI |
100 PSI-D-DO |
-100 to 100 |
PSI |
100 | 2 |
200 PSI |
250 PSI |
100 PSI-A-DO |
0 to 100 |
PSIA |
100 | 2 |
200 PSI |
250 PSI |
General Performance Characteristics (All Models)
Parameter |
Minimum |
Nominal |
Maximum |
Units |
Resolution |
12 |
- | - |
Bit |
Conversion Speed |
- | 8 | 16 |
mS |
Supply Current |
- | 8 | 12 |
mA |
Performance Characteristics for 5 INCH-D-DO
Parameter |
Minimum |
Nominal |
Maximum |
Units |
Overall Accuracy |
- |
0.25 |
0.5 |
%FSO |
Long Term Drift (one year) |
- | - |
0.5 |
%FSO |
Offset Position Sensitivity (1g) |
- | - |
0.05 |
%FSO |
Offset Warm-up Shift |
- | - |
0.25 |
%FSO |
Performance Characteristics for 10 INCH-D-DO and 1 PSI-D-DO
Parameter |
Minimum |
Nominal |
Maximum |
Units |
Overall Accuracy |
- |
0.25 |
0.5 |
%FSO |
Long Term Drift (one year) |
- | - |
0.5 |
%FSO |
Offset Position Sensitivity (1g) |
- | - |
0.03 |
%FSO |
Offset Warm-up Shift |
- | - |
0.25 |
%FSO |
Performance Characteristics for 5 PSI-D-DO through 100 PSI-x-DO
Parameter |
Parameter |
Nominal |
Maximum |
Units |
Overall Accuracy |
- |
0.10 |
0.25 |
%FSO |
Long Term Drift (one year) |
- | - |
0.25 |
%FSO |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃