600 & 601 Series Split-core Current Transformer - 600 & 601 Series
Application: ANSI (Revenue Grade)
Split Core: true
Mount: wire
Frequency: 50-400Hz
Insulation Level: 0.6 kV, BIL 10 kV full wave
Continuous Thermal Current Rating Factor: 1.33 at 30° C amb 1.00 at 55° C amb
Approximate Weight: 1.5 lbs.
- Quantity:
- - +
Product Specification
The 600 & 601 Series Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.
600 & 601 Series Split-core Current Transformer Caution
Proper safety precautions must be followed during installation by a trained electrician. Never install while bus is energized. The current transformer must have its secondary terminals short circuited or the burden connected, before energizing the primary circuit.
600 & 601 Series Split-core Current Transformer Features
Construction: The core and windings are encased in UL approved plastic
Terminals: 8-32 brass studs with one flatwasher and two regular nuts
Flexible Leads: UL 1015 105° C, CSA approved, #16 AWG, 24” long unless otherwise specified
600 & 601 Series Split-core Current Transformer Specifications
Frequency: 50-400Hz
Insulation Level: 0.6 kV, BIL 10 kV full wave
Continuous Thermal Current Rating Factor: 1.33 at 30° C amb 1.00 at 55° C amb
Approximate Weight: 1.5 lbs.
600 & 601 Series Split-core Current Transformer Applications
For Energy Management Systems and Instrumentation
600 & 601 Series Split-core Current Transformer PART NUMBERS
Part Number |
Current Ratio |
VA at 1% Class |
ANSI Metering Class at 60Hz |
Part Number |
Current Ratio |
VA at 1% Class |
ANSI Metering Class at 60Hz |
|||||
BO.1 |
BO.2 |
BO.5 |
|
BO.1 |
BO.2 |
BO.5 |
||||||
600-401 |
400:5A |
1.5 |
2.4 |
|
------ |
|
601-401 |
400:5A |
1.0 |
4.8 |
------ | ------ |
600-501 |
500:5A |
2.0 |
2.4 |
|
------ |
|
601-501 |
500:5A |
1.5 |
4.8 |
4.8 |
------ |
600-601 |
600:5A |
2.5 | 2.4 |
2.4 |
------ |
|
601-601 |
600:5A |
2.0 |
2.4 |
4.8 |
------ |
600-801 |
800:5A |
5.0 | 1.2 | 1.2 |
2.4 |
|
601-801 |
800:5A |
2.5 |
1.2 |
2.4 |
4.8 |
600-102 |
1000:5A |
7.5 | 1.2 |
1.2 |
2.4 |
|
601-102 |
1000:5A |
5.0 |
1.2 |
1.2 |
4.8 |
600-122 |
1200:5A |
15.0 |
0.6 |
1.2 |
1.2 |
|
601-122 |
1200:5A |
10.0 |
1.2 |
1.2 |
2.4 |
600-152 |
1500:5A |
20.0 |
0.6 |
0.6 |
1.2 |
|
601-152 |
1500:5A |
15.0 |
1.2 |
1.2 |
1.2 |
600-162 |
1600:5A |
20.0 |
0.6 |
0.6 |
1.2 |
|
601-162 |
1600:5A |
15.0 | 1.2 |
1.2 |
1.2 |
600-202 |
2000:5A |
30.0 |
0.6 |
0.6 |
0.6 |
|
601-202 |
2000:5A |
20.0 | 0.6 |
0.6 |
1.2 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Three-phase Open Loop Mode Hall Effect Current Sensor
-
High Precision Closed Loop Mode Hall Effect Current Sensor
-
DC Leakage Current Sensor
-
Hall Effect Voltage Sensor
-
Hall Effect Voltage Transmitter
-
RMS Dismountable Hall Effect Current Transmitter
-
Split-core Current Transformer
-
Single Element AC Current Digital Current Transducer
-
Two Element AC Current Digital Current Transducer
-
Three Element AC Current RS485 Digital Current Transducer