14-bit Digital Output Pressure Sensor - MEAS 86BSD

  • 14-bit Digital Output Pressure Sensor
  • 14-bit Digital Output Pressure Sensor
Mouse over image to zoom

• Pressure (bar): 0.07, 0.35, 1, 2, 5, 7, 10, 14, 20
• Pressure (psi): 1, 2, 5, 15, 30, 50, 100, 150, 200, 300
• ±0.25% Accuracy
• ±1.0 Total Error Band
• I2C or SPI Interface protocols
• Compensated Temperature (≤5psi): 0~50°C
• Compensated Temperature (≥15psi): -20~ +80°C

  • Model Number: MEAS 86BSD
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

86BSD Digital Output Pressure Sensor Specifications
• Stainless steel with O-ring seal
• Pressure/temperature read-out
• Digital output
• ASIC calibrated
• Absolute, gage
• Cable/connector option
• Low power option
• 16mm diaphragm diameter

The 86BSD is a small profile, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing. This 14-bit digital output pressure sensor supports I2C and SPI interface protocols, may come in a 3.3 or 5.0Vdc supply voltage and is designed for o-ring mounting. The sensing package utilizes silicone oil to transfer pressure from the 316L stainless steel diaphragm to the sensing element.

The 86BSD is designed for high performance, low pressure applications. A custom ASIC is used for temperature compensation, offset correction, and provides a digital output of 10~90% or 5~95%.

For a similar sensor with stainless steel fittings, refer to the 85BSD digital output pressure sensor.

86BSD Digital Output Pressure Sensor Features
• Mountable with O-ring seal
• ±0.25% Accuracy
• ±1.0 Total Error Band
• Cable/connector option
• Low power option
• I2C or SPI Interface protocols

86BSD Digital Output Pressure Sensor Applications
• Level controls
• Tank level measurement
• Corrosive fluids and gas measurement systems
• Sealed systems
• Manifold pressure measurement
• Barometric pressure measurement
• Submersible depth monitoring

86BSD Digital Output Pressure Sensor Performance Specifications
Supply Voltage: 3.3Vdc
Ambient Temperature: 25°C (unless otherwise specified

Parameters
Min
Typ
Max
Units
Notes
Zero Pressure Output (10% ~ 90%)

666
Count Hex
1
Zero Pressure Output (5% ~ 95%)

333
Count Hex
1
Full Scale Pressure Output (10% ~ 90%)

399A
Count Hex
1
Full Scale Pressure Output (5% ~ 95%)

3CCB
Count Hex
1
Accuracy
-0.25
0.25 %Span
2
Total Error Band
-1
1 %Span
3
Pressure Resolution
0.008

%Span

Temperature Accuracy
-1.5
1.5 °C
4
Resolution – Temperature

0.1
°C

Input Voltage Range
2.7 3.3 5.5 V
1
Supply Current

3
mA

Insulation Resistance (50Vdc)
50

MΩ
5
Overpressure


2X Rated
6
Burst Pressure


3X Rated
7
Load Resistance (RL)
10

KΩ

Long Term Stability (Offset & Span)

±0.5

%Span/Year

Compensated Temperature (≤5psi)
0
50 °C

Compensated Temperature (≥15psi)
-20
+80 °C

Operating Temperature
-40
+125 °C

Storage Temperature
-40
+125 °C
8
Output Pressure Resolution


14 Bits

Output Temperature Resolution
8
11 Bits

Start Time to Data Ready


8.4 ms
9
Output Type
10% to 90% or 5% to 95%
Interface Type
I2C (ADDR, 0x28H)
I2C (ADDR, 0X36H)
I2C (ADDR, 0x46H)
SPI
Media – Pressure
Liquids and gases compatible with 316/316L Stainless Steel
Notes
1.  Measured at vacuum for absolute(A), ambient for gage(G) and sealed gage(S). Output is not ratiometric to supply voltage.
2.  Accuracy: combined linearity, hysteresis and repeatability.
3.  Total Error Band: includes calibration errors and temperature effects over the compensated range. See Figure 3.
4.  The deviation from a best fit straight line (BFSL) fitted to the output measured over the compensated temperature range. For errors beyond the compensated temperature range, See Figure 2.
5.  Between case and sensing element.
6.  2X or 400psi, whichever is less. The maximum pressure that can be applied to a transducer without changing the transducer's performance or accuracy.
7.  3X or 600psi, whichever is less. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
8.  Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
9.  Start time to data ready is the time to get valid data after POR (Power on Reset). The time to get subsequent valid data is then specified by the response time specification.

86BSD Digital Output Pressure Sensor Ordering Information


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service