True RMS AC Voltage Transducer - Single Phase
-
Price
Price on request ≥1piece
-
Model Number
CR4511 -
Data Sheet
-
Package
Original packaging -
Specs
CR4511 -
Quantity
- +Send Inquiry
Find Similar Products
-
AC Current Transformer to DC Current (4-20 mA - Loop Powered)
Model Number:T201
MOQ:1
-
DC Current Trasducer to DC Current (4..20 mA - Loop Powered)
Model Number:T201DC
MOQ:1
-
Loop Powered Transmitter for Pt100 and Ni100 Probes
Model Number:T120
MOQ:1
-
Isolated Loop Powered Universal Temperature Transmitter
Model Number:T121
MOQ:1
-
Passive Current Transducers 100 ADC (4-20 mA - Current Loop)
Model Number:T201DC-100
MOQ:1
-
AC/DC Contactless TRMS Direct and Alternate Current Transformers
Model Number:T201DCH
MOQ:1
Product Description
CR4511 True RMS Voltage Transducers and Transmitters are designed for applications where AC voltage waveforms are not purely sinusoidal. More precise and accurate than other devices, these units are ideal in chopped wave and phase fired control systems.
CR4511 True RMS AC Voltage Transducer Features
• Connection diagram printed on case
• DIN rail mount or panel mount
• Highest precision available
• 24 Vdc powered
• Outputs isolated from inputs
• 0-10 Vdc output
CR4511 True RMS AC Voltage Transducer Specifications
• Thermal Drift: 500 PPM/°C
• Output Load: 2 K or greater
• Supply Voltage: 24 VDC
• Insulation Voltage: 2500 VDC
• Response Time: 250 ms
• Operating Temperature: 0°C to +60°C
• Calibration: True RMS sensing
• Basic Accuracy: 0.5%
• MTBF: Greater than 100 K hours
• Frequency Range: 20 Hz-5 KHz
CR4511 True RMS AC Voltage Transducer Applications
• Chopped waveform drivers
• Phase fired controlled devices
• Quickly varying voltage supplies
• Harmonic voltages
CR4511 True RMS AC Voltage Transducer PART NUMBERS

CR4511 True RMS AC Voltage Transducer Features
• Connection diagram printed on case
• DIN rail mount or panel mount
• Highest precision available
• 24 Vdc powered
• Outputs isolated from inputs
• 0-10 Vdc output
CR4511 True RMS AC Voltage Transducer Specifications
• Thermal Drift: 500 PPM/°C
• Output Load: 2 K or greater
• Supply Voltage: 24 VDC
• Insulation Voltage: 2500 VDC
• Response Time: 250 ms
• Operating Temperature: 0°C to +60°C
• Calibration: True RMS sensing
• Basic Accuracy: 0.5%
• MTBF: Greater than 100 K hours
• Frequency Range: 20 Hz-5 KHz
CR4511 True RMS AC Voltage Transducer Applications
• Chopped waveform drivers
• Phase fired controlled devices
• Quickly varying voltage supplies
• Harmonic voltages
CR4511 True RMS AC Voltage Transducer PART NUMBERS