Ground Fault Current Sensing Relay
-
Price
Price on request ≥1piece
-
Model Number
CR7310 -
Data Sheet
-
Package
Original packaging -
Specs
CR7310 -
Quantity
- +Send Inquiry
Find Similar Products
-
AC Current Transformer to DC Current (4-20 mA - Loop Powered)
Model Number:T201
MOQ:1
-
DC Current Trasducer to DC Current (4..20 mA - Loop Powered)
Model Number:T201DC
MOQ:1
-
Loop Powered Transmitter for Pt100 and Ni100 Probes
Model Number:T120
MOQ:1
-
Isolated Loop Powered Universal Temperature Transmitter
Model Number:T121
MOQ:1
-
Passive Current Transducers 100 ADC (4-20 mA - Current Loop)
Model Number:T201DC-100
MOQ:1
-
AC/DC Contactless TRMS Direct and Alternate Current Transformers
Model Number:T201DCH
MOQ:1
Product Description
CR7310 Ground Fault Current Sensing Relay
The CR7310 Series Ground Fault Sensor provides a reliable and cost effective method for sensing ground faults. The current-carrying wires are routed through the opening extending from the top of the case. When ground current reaches the level set by the trip point adjustment, the relay trips, illuminates the tripped LED and provides an output signal. A precision voltage reference circuit ensures a highly repeatable trip point. The Sensor is rated as a Class 1 device.
CR7310 Ground Fault Sensor Features
• Variable trip point and time delay
• Monitors currents from 10 mAAC to 100AAC
• Electrical isolation between circuits
• Output relay rated up to 20 Amps
• LED trip status indicator
• Dead band prevents relay chatter
• Calibrated dial option available
• External current transformers available
CR7310 Ground Fault Sensor Specifications
• Power-On Delay: 100 ms max
• Input Supply Power: Terminals: 2 - 1/4" Male Q C
• Frequency: 60 to 400 Hz
• Mechanical Life: 10 million operations, typ.@ rated load
CR7310 Ground Fault Sensor Applications
• Monitor electrical heater elements
• Sense motor over/under loads
• Detect lamp burn-out
• Indicate phase loss
CR7310 Ground Fault Sensor PART NUMBER

CR7310 Ground Fault Sensor Features
• Variable trip point and time delay
• Monitors currents from 10 mAAC to 100AAC
• Electrical isolation between circuits
• Output relay rated up to 20 Amps
• LED trip status indicator
• Dead band prevents relay chatter
• Calibrated dial option available
• External current transformers available
CR7310 Ground Fault Sensor Specifications
• Power-On Delay: 100 ms max
• Input Supply Power: Terminals: 2 - 1/4" Male Q C
• Frequency: 60 to 400 Hz
• Mechanical Life: 10 million operations, typ.@ rated load
CR7310 Ground Fault Sensor Applications
• Monitor electrical heater elements
• Sense motor over/under loads
• Detect lamp burn-out
• Indicate phase loss
CR7310 Ground Fault Sensor PART NUMBER