• Ultra-Low Power Analog Nitrogen Dioxide Sensor Module
  • Ultra-Low Power Analog Nitrogen Dioxide Sensor Module
Mouse over image to zoom

Ultra-Low Power Analog Nitrogen Dioxide Sensor Module

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    ULPSM-NO2 968-047
  • Data Sheet

  • Package

    Original packaging
  • Specs

    ULPSM-NO2 968-047
  • Quantity

    - +
  • Send Inquiry

Product Description

ULPSM-NO2 968-047 Ultra-Low Power Analog NO2 Sensor Module Description
NOW with SPEC's new 110-507 NO2 sensor with improved low ppb performance and a filter to remove Ozone.

Quickly integrate Nitrogen Dioxide sensing into your system with very low power consumption and a simple analog sensor signal output. 
The ULPSM converts the Nitrogen Dioxide sensor’s linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings.

ULPSM-NO2 968-047 Nitrogen Dioxide Sensor NO2 Sensor Module Benefits
• NEW 110-507 NO2 sensor with O3 filter!
• 0 to 3 V Analog Signal Output

• Low Power Consumption < 45 µW
• Fast Response
• On-board Temperature Sensor
• Easy Sensor Replacement
• Standard 8-pin connector

ULPSM-NO2 968-047 Nitrogen Dioxide Sensor NO2 Sensor Module Applications
• Fixed Industrial Safety Monitoring
• Portable Industrial Safety Monitoring
• Portable Personal Safety Monitor
• Indoor Air Quality Monitoring
• Outdoor Air Quality Monitoring
• Air Purification Control

ULPSM-NO2 968-047 Nitrogen Dioxide Sensor NO2 Sensor Module Performance Characteristics
Measurement Range
0 to 20 ppm
Lower Detection Limit
< 0.1 ppm
Resolution
< 0.1 ppm
Accuracy
< ± 2 % of reading
Response Time T90
< 30 seconds
Power-On Stabilization Time
60 minutes recommended