ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module DESCRIPTION
Quickly integrate Carbon Monoxide Sensing into your system with very low power consumption and a simple analog sensor signal output.
The ULPSM converts the Carbon Monoxide sensor’s linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings.
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module BENEFITS
• 0 to 3 V Analog Signal Output
• Low Power Consumption < 45 µ W
• Fast Response (< 30 seconds)
• On-board Temperature Sensor
• Easy Sensor Replacement
• Standard 8-pin connector
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module APPLICATIONS
• Residential and Commercial CO Monitoring
• Industrial CO Monitors
• Ventilation Control
• RV and Marine CO Monitoring
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module PERFORMANCE CHARACTERISTICS
Quickly integrate Carbon Monoxide Sensing into your system with very low power consumption and a simple analog sensor signal output.
The ULPSM converts the Carbon Monoxide sensor’s linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings.
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module BENEFITS
• 0 to 3 V Analog Signal Output
• Low Power Consumption < 45 µ W
• Fast Response (< 30 seconds)
• On-board Temperature Sensor
• Easy Sensor Replacement
• Standard 8-pin connector
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module APPLICATIONS
• Residential and Commercial CO Monitoring
• Industrial CO Monitors
• Ventilation Control
• RV and Marine CO Monitoring
ULPSM-CO 968-001 Ultra-Low Power Analog CO Sensor Module PERFORMANCE CHARACTERISTICS
Measurement Range |
0 to 500 ppm |
Lower Detection Limit |
2 ppm |
Resolution |
1 ppm |
Accuracy |
< 3 % of reading |
Response Time T90 |
< 30 seconds |
Power-On Stabilization Time |
15 minutes recommended |