Toroidal Conductivity Sensor - SE 680

  • Toroidal Conductivity Sensor
  • Toroidal Conductivity Sensor
  • Toroidal Conductivity Sensor
Mouse over image to zoom

- Compact design
- Competitively priced
- Large measuring range
- Quick-reacting temperature detector
- Digital data transfer
- Completely molded surface
- Ra < 0.4 µm
- Virgin PEEK, FDA type

  • Model Number: SE 680
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

SE 680 Toroidal Conductivity Sensor

High-precision sensor made of FDA-approved PEEKwith an extremely large measuring range. Steam-sterilizable.


The joint- and gap-free, sealless design and stain-resistant surface made of Virgin PEEK make the SE 680 a heavy-duty sensor. The inductive technology is not influenced by polarization and does not have any sensor surfaces subject to corrosion.


SE 680 Toroidal Conductivity Sensor Applications

Fresh water technology, dairy products, breweries, soft drink manufacturing, electroplating, air-conditioning, CIP monitoring in the beverage industry, pharmaceutical applications,­ cooling tower monitoring, on­-site wastewater treatment plants, monitoring concentrations of salt solutions, alkalis and acids, washers, and rinsing processes


SE 680 Toroidal Conductivity Sensor Facts and Features

- Compact design
- Competitively priced
- Large measuring range
- Quick-reacting temperature detector
- Digital data transfer
- Completely molded surface
- Ra < 0.4 µm
- Virgin PEEK, FDA type


SE 680 Toroidal Conductivity Sensor Specifications

Cell factor  c ≈ 5.0/cm
Installation factor  1 (adjustable)
Measuring range  0.002 ... 2000 mS/cm
Error  ± 1 % meas. val. + 0.002 mS/cm, ± 0.02 %/K
Materials with process contact  Virgin PEEK, FDA type
Materials without process contact  PP-ESD
Temperature sensor  Pt1000
Response time  T90 approx. 30 s
Process temperature  -10 ... +125 °C (see PT diagram)
Sterilization  ≤ 5 bar / ≤ 150 °C / ≤ 60 min
Ambient temperature  -20 ... +60 °C
Pressure range Prel  -0.1 ... 10 bar (see PT diagram)
Surface roughness (process-wetted parts)  Ra < 0.4 µm  
Electrical connection  M12 plug, 4-pin;cable length max. 100 m
Certificates
FDA CFR 177.2415; material testing acc. to USP IV 121 °C 
USPandclass VI
Explosion protection:
SE680X-*******M
IECEx TUN 15.0026 X
Ex ia IIC T6/T4/T3 Ga
TÜV 15 ATEX 154534 X
Ex II 1 G Ex ia IIC T6/T4/T3 Ga
Temperature class:
T6
T4
T3
Ambient and process temperature range
-20 °C ≤ Ta ≤ +75 °C
-20 °C ≤ Ta ≤ +125 °C
-20 °C ≤ Ta ≤ +150 °C


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service