Three Element, 4-Wire RS485 AC Voltage Digital Transducer
-
Price
Price on request ≥1piece
-
Model Number
CRD4570 -
Data Sheet
-
Package
Original packaging -
Specs
CRD4570 -
Quantity
- +Send Inquiry
Find Similar Products
-
Three-phase Open Loop Mode Hall Effect Current Sensor
Model Number:TKC-TG3
MOQ:1
-
High Precision Closed Loop Mode Hall Effect Current Sensor
Model Number:TBC-LTHB
MOQ:1
-
DC Leakage Current Sensor
Model Number:TDC-EB
MOQ:1
-
Hall Effect Voltage Sensor
Model Number:TBV-LV
MOQ:1
-
Hall Effect Voltage Transmitter
Model Number:TBV-AS12/24 Series
MOQ:1
-
RMS Dismountable Hall Effect Current Transmitter
Model Number:TKC-KDRA Series
MOQ:1
Product Description
The CRD4500 Series Data Stream Digital Transducers are designed for applications where AC current waveforms are not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase designs. The data is streamed over an RS485 IEEE bus which enables multiple transducers to communicate thru a single master connection. These advanced sensors are ideal for entire plant or zone monitoring. Also, the communication alagorithm can be pre-ordered with ASCII based control or modified MODBUS based control.
CRD4570 AC Voltage Digital Transducer Features
• Heart Beat and Communication Indicators
• Pre-Calibrated with Non-Volatile Memory
• RS485 Output
• Optional MODBUS Output
• Voltage Input up to 600 VAC
• Three Phase 4 Wire
• DIN Rail or Surface Mount
CRD4570 AC Voltage Digital Transducer Specifications
• Basic Accuracy: 0.5%
• Frequency Range 20 Hz to 5 KHz
• Isolation Voltage: 2500 VDC
• Supply Voltage: 24VDC +/- 5%
• Supply Power: Less than 250 mWatts
• Output ESD Protection: +/- 15KV
• Output Resolution: 16 BIT
• Operating Temperature: 0 to 60 ℃
CRD4570 AC Voltage Digital Transducer Applications
• Sub-Metering Energy Measurement
• Motor Loads
• Remote Monitoring
• Automatic Control Systems
• Load Shedding
CRD4570 AC Voltage Digital Transducer Sensing
• True RMS Voltage, Each Phase
CRD4570 AC Voltage Digital Transducer Features
• Heart Beat and Communication Indicators
• Pre-Calibrated with Non-Volatile Memory
• RS485 Output
• Optional MODBUS Output
• Voltage Input up to 600 VAC
• Three Phase 4 Wire
• DIN Rail or Surface Mount
CRD4570 AC Voltage Digital Transducer Specifications
• Basic Accuracy: 0.5%
• Frequency Range 20 Hz to 5 KHz
• Isolation Voltage: 2500 VDC
• Supply Voltage: 24VDC +/- 5%
• Supply Power: Less than 250 mWatts
• Output ESD Protection: +/- 15KV
• Output Resolution: 16 BIT
• Operating Temperature: 0 to 60 ℃
CRD4570 AC Voltage Digital Transducer Applications
• Sub-Metering Energy Measurement
• Motor Loads
• Remote Monitoring
• Automatic Control Systems
• Load Shedding
CRD4570 AC Voltage Digital Transducer Sensing
• True RMS Voltage, Each Phase