Sulfur Dioxide + Hydrogen Sulfide Sensor (SO2 + H2S Sensor) - SOH-A2
• Range: 20ppm SO2 limit of performance warranty
• Range: 100ppm H2S limit of performance warranty
• Sensitivity: 140 to 250 nA/ppm in 10ppm SO2
• Sensitivity: 450 to 900 nA/ppm in 20ppm H2S
• Temperature range: -30 to 50 ℃
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 %rh continuous
• Weight: < 6 g
- Quantity:
- - +
Product Specification
SOH-A2 Sulfur Dioxide + Hydrogen Sulfide Sensor Introduction
Personal gas safety monitors can be found in almost every industry, with the requirement for multiple gas detection becoming commonplace.
Sulfur gases are toxic with a complex chemistry. Measuring both SO2 and H2S provides the information for separating the corrosive gases, but with different toxicologies.
2Sense Dual Gas
Save space and save cost with our 2Sense family of dual gas sensors, in the A-series 20mm size.
With a patented design and best response, these dual sensors offer the required performance with obvious advantages.
SO2 / H2S the SOH-A2 measures the two critical Sulfur gases together within one sensor body and using a software algorithm, separates the two gases for clear discrimination.
Sulfur Dioxide Sensor PERFORMANCE |
||
Sensitivity |
nA/ppm in 10ppm SO2 |
140 to 250 |
Response time |
t90 (s) from zero to 10ppm SO2 |
< 15 |
Zero current |
ppm equivalent in zero air |
< ± 0.2 |
Resolution |
rms noise (ppm equivalent) |
< 0.2 |
Range |
ppm SO2 limit of performance warranty |
20 |
Linearity |
ppm error at full scale, linear at zero and 10 ppm SO2 |
< ±2 |
Overgas limit |
ppm maximum SO2 for stable response to gas pulse |
50 |
|
|
|
Sulfur Dioxide Sensor LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
< 0.5 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 6 |
Operating life |
months until 80% original signal (24 month warranted) |
24 |
|
|
|
Sulfur Dioxide Sensor ENVIRONMENTAL |
||
Sensitivity @ -20°C |
% (output @ -20°C/output @ 20°C) @ 10ppm SO2 |
90 to 100 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 10ppm SO2 |
80 to 100 |
Zero @ -20°C |
ppm equivalent change from 20°C |
-0.2 to 0.2 |
Zero @ 50°C |
ppm equivalent change from 20°C |
0.2 to 0.8 |
|
|
|
Sulfur Dioxide Sensor CROSS SENSITIVITY |
||
Filter capacity |
ppm hours of Hydrogen Sulfide |
nd |
H2S sensitivity |
% measured gas @ 20ppm H2S |
< 15 |
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< -150 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< -50 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 50 |
CO sensitivity |
% measured gas @ 400ppm CO |
< 1 |
H2 sensitivity |
% measured gas @ 400ppm H2 @ 20°C |
< 1 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 40 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 1 |
|
|
|
Sulfur Dioxide Sensor KEY SPECIFICATIONS |
||
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
%rh continuous (see note below) |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 6 |
Hydrogen Sulfide Sensor (H2S Sensor) Specification
Hydrogen Sulfide Sensor PERFORMANCE
Sensitivity
nA/ppm in 20ppm H2S
450 to 900
Response time
t90 (s) from zero to 20ppm H2S @ 20℃
< 25
Zero current
ppm equivalent in zero air
± 0.25
Resolution
rms noise (ppm equivalent)
< 0.1
Range
ppm H2S limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero and 20ppm H2S
< ±5
Overgas limit
maximum ppm H2S for stable response to gas pulse
200
Hydrogen Sulfide Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
< 0.1
Sensitivity drift
% change/year in lab air, monthly test
< 2
Operating life
months until 80% original signal ( 24 month warranted)
24
Hydrogen Sulfide Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 20ppm H2S
75 to 90
Sensitivity @ 50°C
% (output @ 50°C /output @ 20°C) @ 20ppm H2S
100 to 110
Zero @ -20°C
ppm equivalent change from 20°C
±0.2
Zero @ 50°C
ppm equivalent change from 20°C
±0.2
Hydrogen Sulfide Sensor CROSS SENSITIVITY
Filter capacity
ppm.hrs of SO2
nd
NO2 sensitivity
% measured gas @ 10ppm NO2
< -25
Cl2 sensitivity
% measured gas @ 10ppm Cl2
< -20
NO sensitivity
% measured gas @ 50ppm NO
< 15
SO2 sensitivity
% measured gas @ 10ppm SO2
< 30
CO sensitivity
% measured gas @ 400ppm CO
< 1.5
H2 sensitivity
% measured gas @ 400ppm H2
< 0.2
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 0.2
NH3 sensitivity
% measured gas @ 20ppm NH3
< ±0.5
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)