The 613 Series Split Core Current Transformer is designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.
The Model 613-1000T is intended for use with high input impedance devices that require signal voltages up to 5 VAC.
The output can be rectified and filtered for devices requiring DC input. The non-linearity and voltage drop of the rectifiers and filters must be considered in the choice of the loading impedance.
613 Series Split-core Current Transformer Caution
Proper safety precautions must be followed during installation by a trained electrician. Never install while bus is energized. The current transformer must have its secondary terminals short circuited or the burden connected, before energizing the primary circuit.
613 Series Split-core Current Transformer Features
• Construction: The core and windings are encased in UL approved plastic
• Flexible Leads: UL 1015 105° C, CSA approved, #16 AWG, 24" long unless otherwise specified
613 Series Split-core Current Transformer Specifications
• Frequency: 50-400Hz
• Insulation: 0.6 kV, BIL 10 kV full wave
• Continuous Thermal Current Rating Factor
Models 613-101 – 613-401:
1.33 at 30°C amb
1.00 at 55°C amb
Model 613-1000T:
330A at 30°C amb
250A at 55°C amb
• Approximate Weight 1lb
613 Series Split-core Current Transformer Applications
For Energy Management Systems and Instrumentation Equipment
The Model 613-1000T is intended for use with high input impedance devices that require signal voltages up to 5 VAC.
The output can be rectified and filtered for devices requiring DC input. The non-linearity and voltage drop of the rectifiers and filters must be considered in the choice of the loading impedance.
613 Series Split-core Current Transformer Caution
Proper safety precautions must be followed during installation by a trained electrician. Never install while bus is energized. The current transformer must have its secondary terminals short circuited or the burden connected, before energizing the primary circuit.
613 Series Split-core Current Transformer Features
• Construction: The core and windings are encased in UL approved plastic
• Flexible Leads: UL 1015 105° C, CSA approved, #16 AWG, 24" long unless otherwise specified
613 Series Split-core Current Transformer Specifications
• Frequency: 50-400Hz
• Insulation: 0.6 kV, BIL 10 kV full wave
• Continuous Thermal Current Rating Factor
Models 613-101 – 613-401:
1.33 at 30°C amb
1.00 at 55°C amb
Model 613-1000T:
330A at 30°C amb
250A at 55°C amb
• Approximate Weight 1lb
613 Series Split-core Current Transformer Applications
For Energy Management Systems and Instrumentation Equipment