HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Cyanide (HCN)
In manufacturing, the use of Styrene Acrylonitrile for food packaging and other consumer products has increased the danger of HCN generated during fires. Alphasense has responded to this issue with HCN sensors with fast response and stable output.
Available in A, B and D series.
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Cyanide (HCN)
In manufacturing, the use of Styrene Acrylonitrile for food packaging and other consumer products has increased the danger of HCN generated during fires. Alphasense has responded to this issue with HCN sensors with fast response and stable output.
Available in A, B and D series.
HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) PERFORMANCE |
||
Sensitivity |
nA/ppm 20ppm HCN |
30 to 50 |
Response time |
t90 (s) from zero to 20ppm HCN |
< 50 |
Zero current |
ppm equivalent in zero air |
± 5 |
Resolution |
RMS noise (ppm equivalent) |
< 0.3 |
Range |
ppm limit of performance warranty |
50 |
Linearity |
ppm error at full scale, linear at zero, 200ppm HCN |
0 to -4 |
Overgas limit |
maximum ppm for stable response to gas pulse |
250 |
|
|
|
HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
nd |
Sensitivity drift |
% change/year in lab air, monthly test |
nd |
Operating life |
months until 80% original signal (12 month warranted) |
> 12 |
|
|
|
HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) ENVIRONMENTAL |
||
Sensitivity @ -10°C |
% (output @ -20°C/output @ 20°C) @ 20ppm |
55 to 90 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 20ppm |
105 to 120 |
Zero @ -20°C |
ppm equivalent change from20°C |
< ± 1 |
Zero @ 50°C |
ppm equivalent change from 20°C |
< ± 1 |
|
|
|
HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) CROSS SENSITIVITY |
||
H2S sensitivity |
% measured gas @ 20ppm H2S |
< 50 |
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< -120 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< -40 |
NO sensitivity |
% measured gas @ 50ppm NO |
< -1 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
< 25 |
CO sensitivity |
% measured gas @ 400ppm CO |
< 0.1 |
H2 sensitivity |
% measured gas @ 400ppm H2 |
< 0.1 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 0.1 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 5 |
|
|
|
HCN-D4 Hydrogen Cyanide Sensor (HCN Sensor) KEY SPECIFICATIONS |
||
Temperature range |
°C |
-10 to 50 -30 to -10 with reduced sensitivity |
Pressure range |
kPa |
80 to 120 |
Humidity range |
%rh (see note below) |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 2 |