• Humidity with Temperature Sensors
  • Humidity with Temperature Sensors
Mouse over image to zoom

Humidity with Temperature Sensors

ISweek online 2h ago

Shenzhen Isweek Technology Co., Ltd

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    HIH-4602-A/C Series
  • Data Sheet

  • Package

    Original packaging
  • Specs

    HIH-4602-A/C Series
  • Quantity

    - +
  • Send Inquiry

Product Description

Description: 

    HIH-4602-A/C Series Relative Humidity (RH) sensors combine both relative humidity and temperature sensing in a TO-5 housing with a hydrophobic sintered stainless steel filter.

    The laser-trimmed, thermoset polymer capacitive sensing elements have on-chip integrated signal conditioning.

    The temperature sensor is thermally connected with the RH sensor making the HIH-4602-A/C often ideal for measuring dew point and other absolute moisture terms.

    The HIH-4602-A contains an integral thermistor, while the HIH-4602-C contains an integral precision RTD.



Features:

• Near linear voltage output vs %RH

• Laser-trimmed interchangeability

• Enhanced accuracy, fast response

• Chemically resistant

• Stable, low drift performance

• Built-in static protection

• Often ideal for dew point and absolute moisture measurements

• TO-5 housing

 

Potential Applications:

• Refrigeration

• Drying

• Meteorology

• Battery-powered systems

• OEM (Original Equipment Manufacturer) assemblies

 

Performance Specifications (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.):

Parameter

Minimum

Typical

Maximum

Unit

Specific

Note

Interchangeability (first order curve)

—

—

—

—

—

 0% RH to 59% RH

-5

—

5

% RH

—

 60% RH to 100% RH

-8

—

8

% RH

—

Accuracy (best fit straight line)

-3.5

—

+3.5

% RH

1

Hysterisis

—

3

—

% RH

—

Repeatability

—

±0.5

—

% RH

—

Settling time

—

—

70

ms

—

Response time (1/e in slow moving air)

—

50

—

s

—

Stability (at 50% RH in one year)

—

±1.2

—

% RH

—

Voltage supply

4

—

5.8

Vdc

—

Current supply

—

200

500

µA

—

Output voltage temp. coefficient at 50% RH, 5 V

—

-4

—

mV/ºC

—

Voltage output (1st order curve fit)

VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25℃

Temperature compensation

True RH = (sensor RH)/(1.0546-0.00216T), T in℃

Operating temperature

-40[-40]

See Figure 1.

85[185]

℃[ºF]

—

Operating humidity

0

See Figure 1.

100

% RH

2

Storage temperature

-50[-58]

—

125[257]

℃[ºF]

—

Storage humidity

See Figure 2.

% RH

2



Specific Notes:

1. Device is calibrated at 5 Vdc and 25 ºC.

2. Non-condensing environment.

 

General Notes:

• Sensor is ratiometric to supply voltage.

• Extended exposure to >90% RH causes a reversible shift of 3% RH.

• Sensor is light sensitive. For best performance, shield sensor from bright light.