Frequency Transducer - Sine Wave
-
Price
Price on request ≥1piece
-
Model Number
CR6610 -
Data Sheet
-
Package
Original packaging -
Specs
CR6610 -
Quantity
- +Send Inquiry
Find Similar Products
-
AC Current Transformer to DC Current (4-20 mA - Loop Powered)
Model Number:T201
MOQ:1
-
DC Current Trasducer to DC Current (4..20 mA - Loop Powered)
Model Number:T201DC
MOQ:1
-
Loop Powered Transmitter for Pt100 and Ni100 Probes
Model Number:T120
MOQ:1
-
Isolated Loop Powered Universal Temperature Transmitter
Model Number:T121
MOQ:1
-
Passive Current Transducers 100 ADC (4-20 mA - Current Loop)
Model Number:T201DC-100
MOQ:1
-
AC/DC Contactless TRMS Direct and Alternate Current Transformers
Model Number:T201DCH
MOQ:1
Product Description
CR6610 Frequency Transducers and Transmitters are designed to give a DC output that is proportional to an input frequency value. These devices are especially suited to multi-frequency applications.
CR6610 Frequency Transducer Features
• Connection diagram printed on case
• Outputs isolated from inputs
• Ranges available for any application
• Sine waveform
• DIN rail or panel mount
CR6610 Frequency Transducer Specifications
• Operating Temperature: 0°C to +60°C
• Output Load: 0-5 VDC: 2K ohm or Greater
• Supply Voltage: 24 VDC
• Insulation Voltage: 1500 VDC
• MTBF: Greater than 100 K hours
• Thermal Drift: 500 PPM/°C
• Basic Accuracy: 0.5%
• Input Voltage: 20 to 250 V Peak (other voltage ranges available)
• Response Time: 250 ms. 0-90% FS
• Frequency Range: 0 Hz to 2kHz
CR6610 Frequency Transducer Applications
• Power quality monitoring
• Applications monitor generator sets
• Multi-frequency control and monitoring
• Inverter drives and systems
CR6610 Frequency Transducer PART NUMBERS
____Add suffix for input range
100 - 0-100 Hz
500 - 0-500 Hz
5000 - 0-5000 Hz
other ranges available
CR6610 Frequency Transducer Features
• Connection diagram printed on case
• Outputs isolated from inputs
• Ranges available for any application
• Sine waveform
• DIN rail or panel mount
CR6610 Frequency Transducer Specifications
• Operating Temperature: 0°C to +60°C
• Output Load: 0-5 VDC: 2K ohm or Greater
• Supply Voltage: 24 VDC
• Insulation Voltage: 1500 VDC
• MTBF: Greater than 100 K hours
• Thermal Drift: 500 PPM/°C
• Basic Accuracy: 0.5%
• Input Voltage: 20 to 250 V Peak (other voltage ranges available)
• Response Time: 250 ms. 0-90% FS
• Frequency Range: 0 Hz to 2kHz
CR6610 Frequency Transducer Applications
• Power quality monitoring
• Applications monitor generator sets
• Multi-frequency control and monitoring
• Inverter drives and systems
CR6610 Frequency Transducer PART NUMBERS
CR6610 |
- | ____ |
Sine wave sensing with 0 - 5 VDC Output |
100 - 0-100 Hz
500 - 0-500 Hz
5000 - 0-5000 Hz
other ranges available