Electrochemical Hydrogen Chloride Sensor (HCL Sensor)
-
Price
Price on request ≥1piece
-
Model Number
HCl/M-200 -
Data Sheet
-
Package
Original packaging -
Specs
HCl/M-200 -
Quantity
- +Send Inquiry
Find Similar Products
-
Infrared Gas Sensor for Oil Industry Methane Sensor
Model Number:PrimePell
MOQ:1
-
High Resolution Infrared Methane (CH4) Sensor
Model Number:Prime1
MOQ:1
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
Model Number:IRC-A1
MOQ:1
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
Model Number:ISB
MOQ:1
-
Hydrogen Chloride Sensor (HCL Sensor)
Model Number:HCL-A1
MOQ:1
-
Intelligent Methane (CH4) Gas Sensor 0~100% VOL
Model Number:MH-741A
MOQ:1
Product Description
Miniature Gas Sensors
Industry standard for portable gas detectors. Widely-used format for personal safety.
Features
Smallest size
Dimensions
Conforms to 4-Series
Diameter: 20 mm
Height: 16.6 mm
Pin diameter: 1.5 mm
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Applications
• Safety and Environmental Control
• For Portable Gas Detectors
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Physical Characteristics
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Cross Sensitivity Data
Industry standard for portable gas detectors. Widely-used format for personal safety.
Features
Smallest size
Dimensions
Conforms to 4-Series
Diameter: 20 mm
Height: 16.6 mm
Pin diameter: 1.5 mm
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Applications
• Safety and Environmental Control
• For Portable Gas Detectors
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Performance Characteristics
Performance data conditions: 20°C, 50% RH and 1013 mbar
|
Nominal Range |
0 - 200 ppm |
|
Maximum Overload |
400 ppm |
|
Expected Operation Life |
2 years in air |
|
Output Signal |
80 ± 30 nA/ppm |
|
Resolution |
1.5 ppm |
|
Temperature Range |
-20°C to 45°C |
|
Pressure Range |
Atmospheric |
|
Pressure Coefficient |
No data |
|
T90 Response Time |
< 60 sec |
|
Relative Humidity Range |
15 % to 90 % R.H. non-condensing |
|
Typical Baseline Range (pure air, 20°C) |
-5 to +5 ppm |
|
Maximum Zero Shift (+20°C to +40°C) |
N.D. |
|
Expected Long Term Output Drift |
< 2% signal loss/month |
|
Recommended Load Resistor |
10 - 20 Ohm |
|
Bias Voltage |
Not allowed |
|
Repeatability |
< 2 % of signal |
|
Output Linearity |
Linear |
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Physical Characteristics
|
Weight |
~ 5.4 g |
|
Position Sensitivity |
None |
|
Storage Life |
Six months in container |
|
Recommended Storage Temperature |
5°C - 20°C |
|
Warranty Period |
12 months from date of dispatch |
HCl/M-200 Hydrogen Chloride Sensor (HCL Sensor) Cross Sensitivity Data
|
Interfering Gas |
Concentration |
Reading |
|
CO |
1000 ppm |
0 ppm |
|
H2 |
1% |
0 ppm |
|
Isopropanol |
vapor |
0 ppm |
|
Ethylene |
100 ppm |
0 ppm |
|
SO2 |
100 ppm |
0 ppm |
|
H2S |
20 ppm |
31 ppm |
|
NO |
25 ppm |
0 ppm |
|
NO2 |
20 ppm |
0 ppm |