Average RMS AC Voltage Transducer
-
Price
Price on request ≥1piece
-
Model Number
CR4810 -
Data Sheet
-
Package
Original packaging -
Specs
CR4810 -
Quantity
- +Send Inquiry
Find Similar Products
-
Three-phase Open Loop Mode Hall Effect Current Sensor
Model Number:TKC-TG3
MOQ:1
-
High Precision Closed Loop Mode Hall Effect Current Sensor
Model Number:TBC-LTHB
MOQ:1
-
DC Leakage Current Sensor
Model Number:TDC-EB
MOQ:1
-
Hall Effect Voltage Sensor
Model Number:TBV-LV
MOQ:1
-
Hall Effect Voltage Transmitter
Model Number:TBV-AS12/24 Series
MOQ:1
-
RMS Dismountable Hall Effect Current Transmitter
Model Number:TKC-KDRA Series
MOQ:1
Product Description
CR4810 Average RMS Voltage Transducers and Transmitters are designed to provide a DC output proportional to the AC voltage input. These devices are best suited for general applications, such as fixed frequency voltage supplies.
CR4810 Average RMS AC Voltage Transducer Features
• 35mm DIN rail mount or panel mount
• 0-5 Vdc output
• 24 Vdc powered
• Outputs isolated from inputs
• Connection diagram printed on case
CR4810 Average RMS AC Voltage Transducer Specifications
• Basic Accuracy: 0.5%
• Calibration: Average RMS sensing
• Thermal Drift: 500 PPM/°C
• Operating Temperature: 0°C to +60°C
• Installation Catagory: CAT II
• Polution Degree: 2
• Response Time: 250 ms
• Altitude: 2000 meter max.
• Insulation Voltage: 2500 Vdc
• Supply Voltage: 24 Vdc ±10%
• Frequency Range: 50 Hz - 400 Hz
• Cleaning: Water-dampened cloth
• MTBF: Greater than 100 K hours
• Output Load: 0-5 Vdc - 2 K Ω
• Relative Humidity: 80% for temperatures up to 31°C and decreasing linearly to 50% at 40°C
CR4810 Average RMS AC Voltage Transducer Applications
• Monitor Motor Faults
• Monitor Heating Elements
• Monitor Lighting Elements
• Remote Voltage Sensing
CR4810 Average RMS AC Voltage Transducer PART NUMBERS

CR4810 Average RMS AC Voltage Transducer Features
• 35mm DIN rail mount or panel mount
• 0-5 Vdc output
• 24 Vdc powered
• Outputs isolated from inputs
• Connection diagram printed on case
CR4810 Average RMS AC Voltage Transducer Specifications
• Basic Accuracy: 0.5%
• Calibration: Average RMS sensing
• Thermal Drift: 500 PPM/°C
• Operating Temperature: 0°C to +60°C
• Installation Catagory: CAT II
• Polution Degree: 2
• Response Time: 250 ms
• Altitude: 2000 meter max.
• Insulation Voltage: 2500 Vdc
• Supply Voltage: 24 Vdc ±10%
• Frequency Range: 50 Hz - 400 Hz
• Cleaning: Water-dampened cloth
• MTBF: Greater than 100 K hours
• Output Load: 0-5 Vdc - 2 K Ω
• Relative Humidity: 80% for temperatures up to 31°C and decreasing linearly to 50% at 40°C
CR4810 Average RMS AC Voltage Transducer Applications
• Monitor Motor Faults
• Monitor Heating Elements
• Monitor Lighting Elements
• Remote Voltage Sensing
CR4810 Average RMS AC Voltage Transducer PART NUMBERS