Average RMS AC Current Transducer - Single Element
-
Price
Price on request ≥1piece
-
Model Number
CR4420 -
Data Sheet
-
Package
Original packaging -
Specs
CR4420 -
Quantity
- +Send Inquiry
Find Similar Products
-
Three-phase Open Loop Mode Hall Effect Current Sensor
Model Number:TKC-TG3
MOQ:1
-
High Precision Closed Loop Mode Hall Effect Current Sensor
Model Number:TBC-LTHB
MOQ:1
-
DC Leakage Current Sensor
Model Number:TDC-EB
MOQ:1
-
Hall Effect Voltage Sensor
Model Number:TBV-LV
MOQ:1
-
Hall Effect Voltage Transmitter
Model Number:TBV-AS12/24 Series
MOQ:1
-
RMS Dismountable Hall Effect Current Transmitter
Model Number:TKC-KDRA Series
MOQ:1
Product Description
The CR4420 Series Average RMS Current Transducers and Transmitters are designed to provide a calibrated DC output proportional to the AC current input. Designed for multi-point current sensing, these devices provide excellent features in a high value package. Average RMS is recommended when sensing current waveforms that have a fixed frequency, and are usually for loads operated from standard utility power.
CR4420 Average RMS AC Current Transducer Features
• Analog 4 - 20 mA DC output
• 24 VDC powered
• Use with external C/T's
• Highest precision available
• Connection diagram printed on case
• DIN Rail or Panel Mount
CR4420 Average RMS AC Current Transducer Specifications
• Frequency Range: 50 Hz - 400 Hz
• Calibration: Average Sensing, RMS Calibrated
• Basic Accuracy: 0.5%
• Output Load: 0 - 300Ω
• Power Source: 24 VDC
• Insulation Voltage: 2500 VDC
• Response Time: 250 ms
• MTBF: Greater than 100 K hours
• Operating Temperature: 0°C to +50°C
• Thermal Drift: 500 PPM/°C
CR4420 Average RMS AC Current Transducer Applications
• Multi-point Current Sensing and Control Panels
• Monitor Motor Faults
• Monitor Heating Elements
• Monitor Lighting Elements
CR4420 Average RMS AC Current Transducer PART NUMBERS

CR4420 Average RMS AC Current Transducer Features
• Analog 4 - 20 mA DC output
• 24 VDC powered
• Use with external C/T's
• Highest precision available
• Connection diagram printed on case
• DIN Rail or Panel Mount
CR4420 Average RMS AC Current Transducer Specifications
• Frequency Range: 50 Hz - 400 Hz
• Calibration: Average Sensing, RMS Calibrated
• Basic Accuracy: 0.5%
• Output Load: 0 - 300Ω
• Power Source: 24 VDC
• Insulation Voltage: 2500 VDC
• Response Time: 250 ms
• MTBF: Greater than 100 K hours
• Operating Temperature: 0°C to +50°C
• Thermal Drift: 500 PPM/°C
CR4420 Average RMS AC Current Transducer Applications
• Multi-point Current Sensing and Control Panels
• Monitor Motor Faults
• Monitor Heating Elements
• Monitor Lighting Elements
CR4420 Average RMS AC Current Transducer PART NUMBERS
