NH3 3E 100 Ammonia Sensor (NH3 Sensor) FEATURES
• Amperometric 3 electrode sensor cell
• Fixed organic gel electrolyte
• No CO2 interference
• 0 volt bias operation
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TYPICAL APPLICATIONS
• TLV-monitoring, leakage detection
• Fixed point applications in cold storages & refrigeration plants only
• For other applications please use NH3 3E SE versions
• No background concentrations of ammonia & alcohols
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TECHNICAL SPECIFICATIONS
Safety Note
This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property.
• Amperometric 3 electrode sensor cell
• Fixed organic gel electrolyte
• No CO2 interference
• 0 volt bias operation
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TYPICAL APPLICATIONS
• TLV-monitoring, leakage detection
• Fixed point applications in cold storages & refrigeration plants only
• For other applications please use NH3 3E SE versions
• No background concentrations of ammonia & alcohols
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TECHNICAL SPECIFICATIONS
|
Measuring Range |
0-100 ppm |
|
Sensitivity Range |
90 nA/ppm ± 40 nA/ppm |
|
Zero Current at 20°C |
< ± 150 nA |
|
Resolution at 20°C |
< 2 ppm |
|
Bias Potential |
0 mV |
|
Linearity |
<5% full scale |
|
Response Time at 20°C t50 t90 |
<20s calculated from 5 min. exposure time <120s calculated from 5 min. exposure time |
|
Long Term Sensitivity Drift |
<10% per 6 months |
|
Operation Conditions Temperature Range Humidity Range |
-40°C to +40°C 15-90% r.H, non-condensing |
|
Effect of Humidity |
an abrupt change of r.H. will cause a short term drift of zero reading |
|
Sensor Life Expectancy |
> 18 months in air |
|
Warranty |
12 months |
Safety Note
This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property.