• UV Radiometer 5.0
  • UV Radiometer 5.0
Mouse over image to zoom

UV Radiometer 5.0

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    GUVx-T1xGS5-LA2
  • Data Sheet

  • Package

    Original packaging
  • Specs

    GUVx-T1xGS5-LA2
  • Quantity

    - +
  • Send Inquiry

Product Description

GUVx-T1xGS5-LA2 UV Radiometer 5.0 Description
 Display : Absolute Power (AP), Relative Power (RP), and Accumulative Time (AT)
 Output : DC Voltage, Current, and Relay

GUVx-T1xGS5-LA2 UV Radiometer 5.0 Applications
 UV Curing

GUVx-T1xGS5-LA2 UV Radiometer 5.0 Constitution
 Display, Sensor Probe


Sensor Probe Dimensions

Size (mm3)
Window (mm)
Weight (g)
Case Material
Cable Length (m)
55 x 30 x 16 12 57 AL-60 5

GUVx-T1xGS5-LA2 UV Radiometer 5.0 Absolute Maximum Ratings
Parameter
Value
Unit
Remark
Operating Temperature
-30 ~ 85
°C
Sensor Probe
0 ~ 50
°C
Display
Working humidy
35 ~ 85
%RH
Display
Power Supply
85 ~ 265
VAC
50/60 ㎐

Parameter
Min.
 Peak
 Max.
Unit
Remark
Detection Power Range
0

19,999 μW/cm2
Detection Range
GUVV-T10GS5-LA2
230 350 395 nm 10% of Max
GUVB-T11GS5-LA2
220 300 320 nm
GUVC-T10GS5-LA2
220 254 280 nm
GVBL-T12GS5-LA2
330 385 445 nm

GUVx-T1xGS5-LA2 UV Radiometer 5.0 Function
 1. Display : Absolute Power (μW/cm2) , Relative Power (%), and Accumulative Time (Hours).
 2. Output : DC Voltage (1~5V DC), DC Current (4-20mA, 300 Ω max load), Relay (NC/NO, 250VAC 3A/30VDC 3A)