Miniature Size Oxygen Sensor (O2 Sensor)
-
Price
Price on request ≥1piece
-
Model Number
O2-G2 -
Data Sheet
-
Package
Original packaging -
Specs
O2-G2 -
Quantity
- +Send Inquiry
Find Similar Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
Model Number:CozIR-A
MOQ:1
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
Model Number:COZIR-W/ExplorIR-W
MOQ:1
-
Oxygen Gas Sensor (O2 Sensor)
Model Number:O2-M2
MOQ:1
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
Model Number:MisIR
MOQ:1
-
Probe Type NDIR CO2 Sensor
Model Number:COZIR-Probe
MOQ:1
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
Model Number:SprintIR-WF
MOQ:1
Product Description
O2-G2 Oxygen Sensor (O2 Sensor) Description
Alphasense Oxygen sensors use capillary flow control.
Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.
Standard galavanic sensors use lead for greatest reliability but fixed lifetime.
O2-G2 Oxygen Sensor size:
Miniature, proven long-term performance. The sensors are designed for the next generation of portable gas detectors. Part of the Alphasense ‘D‘ family.
O2-G2 Oxygen Sensor (O2 Sensor) Key Features & Benefits:
Small Footprint
Reduced Height
Low Weight
Good Connectivity: Uses industry standard, low cost, Molex sockets for direct board insertion.
Reduced Costs: High quality design with a significant reduction in the cost per measured gas, allied to reduced manufacturing costs are passed on to OEMs
O2-G2 Oxygen Sensor (O2 Sensor) PERFORMANCE
Output
μA @ 22℃, 20.9% O2
30 to 42
Response time
t90 (s) from 20.9% to 0% O2 (47Ω)
< 20
Zero current
μA @ 99.99% N2 , 22℃
< 2.5
O2-G2 Oxygen Sensor (O2 Sensor) LIFETIME
Output drift
% change in output @ 3 months
< 2
Operating life
months until 85% original output in 20.9% O2
> 24
O2-G2 Oxygen Sensor (O2 Sensor) ENVIRONMENTAL
Humidity Sensitivity
% O2 change: 0% to 95% rh @ 40℃
< 0.7
Pressure sensitivity
(% change of output)/(% change of pressure) @ 20kPa
< 0.1
CO2 sensitivity
% change in output / % CO2 @ 5% CO2
< 0.1
Output at -20℃
% output/output at 20℃ in 20.9% O2
87 to 93
Output at +50℃
% output/output at 20℃ in 20.9% O2
103 to 107
O2-G2 Oxygen Sensor (O2 Sensor) KEY SPECIFICATIONS
Temperature range
℃
-30 to 55
Pressure range
kPa
80 to 120
Humidity range
% rh continuous (0 to 99% rh short term)
5 to 95
Storage period
months @ 3 to 20℃ (store in sealed pot)
6
Load resistor
Ω (recommended)
47 to 100
Weight
g
< 7