Hydrogen Sensor H2 Sensor - SenseH2
• H2 range (in air): 0.25 - 4% H2
• Voltage input: 12 - 24Vdc
• Output (sensing range): 1 - 4.5Vdc
• Response time (T90): 5 Sec.
• Recovery time (T10): 5 Sec.
• Ambient temperature: -20~80°C
• Relative humidity: 5~95%R.H.
• UL Classified, ATEX, CE for hazardous locations
- Quantity:
- - +
Product Specification
SenseH2 Hydrogen Sensor (H2 Sensor) Features
• High sensitivity and selectivity to hydrogen
• Fast response and recovery times
• Immune to signal saturation
• Robust to widely varying ambient flow rates
• Compact and rugged design
• 1.0 to 4.5V output, spans 0.25 to 4.0% H2 in air(5 to 100% LFL)
• UL Classified, ATEX, CE for hazardous locations
SenseH2 Hydrogen Sensor (H2 Sensor) Overview
Designed for hydrogen monitoring, this ceramic sensor exhibits a highly sensitive, selective, and rapid response to the presence of hydrogen in ambient air. It reliably measures H2 concentrations over a wide range of temperature and humidity variation and provides a repeatable response, even in the presence of other combustible gases. Additionally, the NTM SenseH2® hydrogen sensor is immune to signal saturation upon continuous exposure to low levels of hydrogen, and recovers rapidly and completely upon hydrogen removal.
SenseH2 Hydrogen Sensor (H2 Sensor) System Components
Sensor: The sensor element employs a patent-pending, chemi-resistive ceramic technology, which provides accurate
and reliable hydrogen detection.
Electronics package: The sensor provides a simple interface with a ratio-metric voltage output (1 to 4.5 VDC; 500mV increments), calibrated to detect up to 4% H2 in air (100% of the LFL). Diagnostic states (<1V, >4.5V) are provided to indicate error conditions. Microprocessor - based heater control ensures stable operation, in temperatures ranging from -20 to 80°C. The compact, rugged design and waterproof connector enable use of the NTM SenseH2 hydrogen sensor in a range of application conditions. Mating connectors can be purchased separately for ease of installation.
SenseH2 Hydrogen Sensor (H2 Sensor) Table of Typical Characteristics
Metric | Min | Max | Units |
Characteristics: | |||
H2 range (in air) | 0.25 | 4 | % |
Voltage input | 12 | 24 | Vdc |
Output (sensing range) | 1 | 4.5 | Vdc |
Error state (output signal) | 0.5 | 0.5 | Vdc |
Error state (output signal) | 4.75 | 4.75 | Vdc |
Power consumption (25°C) | 0.1 | 0.15 | A |
Response time (T90) | --- | 5 | Sec. |
Recovery time (T10) | --- | 5 | Sec. |
Environmental Conditions: | |||
Ambient temperature | -20 | 80 | °C |
Relative humidity | 5 | 95 | %R.H. |
Linear flow rate | 0.02 | 5 | m/s |
Hazardous Location Approvals: |
UL Class I, Div 2, GR A-D, T2B
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)