Analogue Evaluation Board for p-Type Metal Oxide Sensors - Metal Oxide Transmitter

  • Analogue Evaluation Board for p-Type Metal Oxide Sensors
  • Analogue Evaluation Board for p-Type Metal Oxide Sensors
Mouse over image to zoom

• Gas/ vapours detected​: H2S, VOCs and CO​
• Sensor type​: Alphasense p-type metal oxide gas sensor​
• Power input​: 5-6 VDC
• Voltage output: 0 to 4.75 VDC​
• Usage/storage range​: -30 to +50 °C (-22 to +122 °F)​
• Usage humidity​: 0% to 95% (non-condensing)​

  • Model Number: Metal Oxide Transmitter
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Analogue Evaluation Board for p-Type Metal Oxide Sensors

Introduction and specification
This Evaluation Board measures the sensor signal and controls the heater for a p-type metal oxide gas sensor. This Evaluation Board includes:
    • Buffered voltage outputs for heater voltage and sensor resistance measurement
    • Integrated two-temperature heater pulsing for optimum sensor performance
    • Selectable sensor resistance ranges for low and high gas concentrations

Please read these instructions to ensure correct installation and use of your p-type metal oxide gas sensor.

P-type Metal Oxide Transmitter Specification

Gas/ vapours detected
H2S, VOCs and CO
Sensor type
Alphasense p-type metal oxide gas sensor
Performance
See H2S, VOC and CO web technical datasheets
Warm-up time
10 minutes to full specification; 30 seconds to reading
Power input
5-6 VDC
Transient current: 700 mA (~10s)
Operating current: 200 mA
Voltage output
0 to 4.75 VDC
Connector
6-pin Molex plug
    Pin 1 (power)
    Pin 2 (supply ground)
    Pin 3 (sensor signal)
    Pin 4 (signal ground)
    Pin 5 (heater power)
    Pin 6 (heater ground)
Sensor power select
(sensor resistance range)
Selectable (LK2)
    low range (up to 1MΩ)
    high range (up to 3MΩ)
Heater two-temp control
User selectable (LK3)
Two-temperature pulsing period
User selectable (LK1)
    5 minute measurement cycle, 60 second clean cycle
    10 minute measurement cycle, 60 second clean cycle
Heater adjustment
10-turn potentiometer to set heater resistance (VR1)
Usage/storage range
-30 to +50 °C (-22 to +122 °F)
Usage humidity
0% to 95% (non-condensing)

Replacement/ additional parts ordering for P-type Metal Oxide transmitter
Replacement and spare parts can be ordered by quoting the part numbers below.
Part Number
Description
034-0025-00
M6 Nylon washer
010-0178-02
ISB Transmitter Lead
029-0059-00
Foam Seal 'A' Series 4-20mA Gas Hood (For use with TO5 Gas Hood)
029-0068-00
Foam Seal (For use with ATEX & 6 Pin Plastic Gas Hood)
033-0012-00
M3 x 20mm long Pillar (Individual part number).
000-GSHD-08
MOX Evaluation Gas Hood Assembly for MOX ATEX
000-GSHD-09
MOX Evaluation Gas Hood Assembly for MOX 6 Pin Plastic
000-GSHD-10
MOX Evaluation Gas Hood Assembly for MOX TO5
HS2, VOC and CO
(all packages)
Replacement sensor.
Heater recalibration will be required.

If you cannot find what you want, you can entrust OFweek to source for you. Just click: