15x15 Ethanol Sensor 1000 ppm Package 110-202 - 3SP_Ethanol_1000 P

  • 15x15 Ethanol Sensor 1000 ppm Package 110-202
  • 15x15 Ethanol Sensor 1000 ppm Package 110-202
Mouse over image to zoom

• Measurement Range: 0 to 1000 ppm
• Resolution: < 5 ppb (instrumentation dependent)
• Repeatability: < +/- 3 % of reading
• Response Time: < 180 seconds typical
• Sensitivity: 15 +/- 6 nA/ppm
• Operating Temperature: -30 to +55°C
• Operating Humidity: 0 to 100% RH non-condensing
• ROHS Compliant

  • Model Number: 3SP_Ethanol_1000 P
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

3SP_Ethanol_1000 P
15x15 Ethanol Sensor 1000 ppm Package 110-202


3SP_Ethanol_1000 P Ethanol Sensor Description

SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.


3SP_Ethanol_1000 P 
Ethanol Sensor Benefits

• Small Size with Low Profile (20x20x3 mm)
• Long Life (10 years expected life)
• Fast Response
• Low Power Consumption
• Individually Calibrated (NIST Traceable)
• ROHS Compliant

 

3SP_Ethanol_1000 P Ethanol Sensor Applications
• Law Enforcement Breathalyzers
• Evidential Breath Alcohol Testing
• Portable Breath Alcohol Tester
• Personal Breathalyzers

3SP_Ethanol_1000 P Ethanol Sensor Specifications

Measurement Range

 0 to 1000 ppm

Resolution

 < 5 ppb (instrumentation dependent)

Repeatability

 < +/- 3 % of reading

Response Time

 < 180 seconds typical

Sensitivity

 15 +/- 6 nA/ppm

Expected Operating Life

 > 5 years (10 years @ 23+/-3°C; 40+/-10% RH)

Operating Temperature Range

 -30 to +55°C (-20 to 40°C recommended))

Operating Humidity Range - non-condensing

 0 to 100% RH (15 to 95% recommended)

Power Consumption

 10 to 50 uW (circuit & ambient Ethanol dependent)


3SP_Ethanol_1000 P Ethanol Sensor Cross Sensitivity

Gas/Vapor

Concentration

Typical Response PPM Ethanol

Methane

500 ppm

< 5

Ammonia

100 ppm

< 5

Nitrogen Dioxide

10 ppm

< 5

Hydrogen Sulfide

25 ppm

63.2

Carbon Monoxide

400 ppm

251.4

Ozone

5 ppm

< 5

Sulfur Dioxide

20 ppm

11.6

Nitric Oxide (NO)

50 ppm

54.5

Chlorine

10 ppm

-14.3

n-Heptane

500 ppm

-12.6


If you cannot find what you want, you can entrust OFweek to source for you. Just click: