Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor - OSS-2
• Measures Oxygen From 0 to 100%
• Electrochemical Fuel Cell Sensor Technology
• Self-Contained, No Need To Add Electrolyte
• Excellent Stability, Performance, & Linearity
• Competitive Drop-In Field Replacement
- Quantity:
- - +
Product Specification
OSS-2 Electrochemical Oxygen Sensor Advantage:
• Measures Oxygen From 0 to 100%
• Electrochemical Fuel Cell Sensor Technology
• Self-Contained, No Need To Add Electrolyte
• Excellent Stability, Performance, & Linearity
• Competitive Drop-In Field Replacement
OSS-2 Electrochemical Oxygen Sensor Description:
The OSS-2 oxygen sensor provides high levels of accuracy, reliability, and linearity throughout its measurement ranges. The oxygen sensor is based on the galvanic electrochemical fuel cell principle and is manufactured in-house under a strict quality procedure.
Backed with excellent customer service and an industry proven product design, our sensors excel in performance and quality while reducing the cost of ownership.
Varying performance advantages to the Southland Sensing Ltd. sensors can be attributed to minor modifications in dimensions, connections, and packaging. However, the principle of operation and the basic components remain the same.
Along with excellent performance and exceptional quality, Southland Sensing offers rapid delivery times to a global customer base for most oxygen sensors.
OSS-2 Electrochemical Oxygen Sensor Specifications:
Sensor Technology |
Electrochemical |
Signal Output1 |
9 - 13 mV |
Measuring Range |
0 - 100 Percent |
Response Time T90 |
6 Seconds |
Accuracy Full Scale2 |
± 1% of Signal |
Repeatability F.S. |
± 0.5% |
Temperature |
Compensated |
Operating Temp |
0 to 50℃ |
Storage Temp |
0 to 45℃ |
Recommended Flow |
0.4 - 20 SCFH |
Housing Material |
White ABS |
Humidity |
0 - 100% RH(Non - Condensing) |
Expected Life3 |
< 60 Months |
Storage |
12 Months |
Warranty4 |
12 Months |
Zero Signal in N2 @ 20℃ |
< 200 uV |
2. Full Scale accuacy is calculated with constant pressure, temperature and proper calibration (80% O2 value on full scale range). Drastic temperature change can result in a maximum error of ± 10%.
3. Expected life is calculated when O2 < 20.9% @ 25 º C, sea level.
4. Southland Sensing Ltd. warrants the sensors for the period noted above to be free from defects in materials and workmanship. Southland Sensing will not be held liable for sensors damaged due to customer neglect.
4. Southland Sensing Ltd. sensors are tested and validated to BSI Standard BS EN 50104:2010
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Oxygen Analyzer
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Oxygen(O2)Gas Sensor
-
Oxygen(O2)Gas Sensor
-
High Quality O2 Sensors