Zirconium dioxide (ZrO2) sensing elements
Long life, non-depleting technology
Integral heating element

  • Model Number: O2S-FR-T6
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Zirconia O2 Sensors Screened Probe Series  Long Housing O2S-FR-T6 FEATURES:
• Zirconium dioxide (ZrO2) sensing elements
• Long life, non-depleting technology
• Integral heating element
• High accuracy
• Requires an external interface board to operatea

• 1.2m Screened cable


Zirconia O2 Sensors Screened Probe Series  Long Housing O2S-FR-T6 BENEFITS:
• No reference gas required
• No need for temperature stabilisation
• Three lengths available; 220mm, 400mm and 600mm
• Screened for use in industrial environments



Zirconia O2 Sensors Screened Probe Series  Long Housing O2S-FR-T6 Specifications:

Heater voltageb

 

Operating (<15s response)

4.2VDC±0.1VDC (~1.7A)

Standby

2VDC (~0.85A)

Operating (<4s response)

4.55VDC±0.1VDC (~1.85A)

Standby

2VDC (~0.85A)

Pump impedance at 700°C

< 6kΩ

Permissible gas temperature

-100°C to +400°C

Gas flow rate

0 - 10 m/s

Repetitive permissible acceleration

5g

Incidental permissible acceleration

30g

OUTPUT VALUES

 

Oxygen pressure range

2mbar—3bar max

Accuracy

5mbar max

Internal operational temperature

700°C

Response time (10—90% step)

 

Standard response sensor

< 15s

Fast response sensor

< 4s

Warm up time (prior to sensor operation)

60s

Warm up time (from standby)

20s

Output stabilisation time

~ 180s






If you cannot find what you want, you can entrust OFweek to source for you. Just click: