Ultra Low Power Digital Output NDIR CO2 Gas Sensor - CozIR-A

  • Ultra Low Power Digital Output NDIR CO2 Gas Sensor
  • Ultra Low Power Digital Output NDIR CO2 Gas Sensor
  • Ultra Low Power Digital Output NDIR CO2 Gas Sensor
Mouse over image to zoom

Ultra-low Power 3.5mW
Measurement ranges from 0 to 1%
Accuracy: ±50 ppm +/- 3% of reading
Operating Pressure Range: 950 mbar to 1050 mbar
Low noise measurement (<10ppm)
3.3V supply.
Peak current only 33mA.
Optional Temperature and Humidity Output.

  • Model Number: CozIR-A
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

COZIR-A Ultra Low Power Digital Output NDIR CO2 Gas Sensor Summary
COZIR is an ultra low power (3.5mW), high performance CO2 sensor, ideally suited for battery operation and portable instruments. Based on GSS IR LED and Detector technology, and innovative optical designs, the COZIR offers the lowest power NDIR sensor available.Optional temperature, humidity and light sensing are  available. COZIR is a third generation product from GSS - leaders in IR LED CO2 sensing.

With measurement ranges of 0-2000ppm, 0-5000ppm and 0-1% the COZIR Ambient Sensor is suitable for applications such as Building Control and Horticulture.

    • Ultra-low Power 3.5mW
    • Measurement ranges from 0 to 1%
    • Low noise measurement (<10ppm)
    • 3.3V supply. 
    • Peak current only 33mA.
    • Optional Temperature and Humidity Output.

COZIR-A NDIR CO2 Gas Sensor Specification

General Performance
Warm-up Time
< 10s. 1.2 secs to first reading. 
Operating Conditions

0°C to 50°C (Standard)

-25°C to 55°C (Extended range)

0 to 95% RH, non-condensing

Recommended Storage
-30°C to +70°C
CO2 Measurement
Sensing Method

Non-dispersive infrared (NDIR) absorption

Patented Gold-plated optics

Patented Solid-state source and detector

Sample Method
Diffusion
Measurement Range
0-2000ppm, 0-5000ppm, 0-1%
Accuracy
±50 ppm +/- 3% of reading
Calibration 
Autocalibration
Non Linearity
< 1% of FS
Pressure Dependence
0.13% of reading per mm Hg in normal atmospheric conditions.
Operating Pressure Range
950 mbar to 1050 mbar
Response Time

30 secs to 3 mins (Configurable via filter type and application)

Reading refreshed twice per second.

Electrical/ Mechanical
Power Input

3.25 to 5.5V. (3.3V recommended).

Peak Current 33mA.

Average Current <1.5mA.

Power Consumption
3.5 mW


COZIR-A NDIR CO2 Gas Sensor Dimensions and Wiring Connections
2x5 0.1” header. view from underside (connector side)


Function
 Pin # 
 Pin # 
Function 
GND
1 2 N/C
+3.3V
3 4 N/C
Sensor Rx (in)
5 6 N/C
Sensor Tx (out)
7 8 Nitrogen Zero 
Analogue O/P
9 10 Fresh Air Zero


COZIR-A NDIR CO2 Gas Sensor  Product picture:

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service