OEM OZONE CONTROLLER - OEM-2
Sensor: Heated metal oxide semiconductor.
Range: 0-0.1 ppm, 0-1 ppm and 0-10 ppm available. Accuracy: 20%.
Sensitivity: As low as 0.02 ppm for the 0.1 ppm module, 0.1 ppm for the 1 ppm module, and 0.3
- Quantity:
- - +
Product Specification
OEM-2 OEM OZONE CONTROLLER GENERAL:
The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set point. It is designed to work with plug-in sensor modules for 0-0.1 ppm, 0-1 ppm, and 0-10 ppm. These are specified when ordering by putting the ppm range after the model number. For example, a 0.1 ppm OEM-2 board system would be OEM-2-.1 and the replacement sensor module for it would be SM-1-.1. These same sensor modules also work in our OEM-1 boards, which have features such as being powered by 110/220 VAC. The sensors modules can also be located at a distance from the OEM-2 boards by 2 or 8 meter cables. These are readily available DIN M/F 5 pin extension cables.
One component of the OEM-2 system is the base board which incorporates the power supply, final signal processing, set-point controls, and the output relay. The other component is the sensor mounted with its associated electronics in a cylindrical DIN plug. This is precalibrated in our lab so that the sensor module and main board module together work as a calibrated system. If the sensor module is damaged, it is simply replaced by another precalibrated module.
The design incorporates hysteresis and time delay (set at 8 seconds except for special orders) to eliminate chatter and other excessive interactions between the sensor and generator. The SPDT relay contacts will handle up to 5 amps at 250 volts. The OEM-2 should not be used outdoors or in the presence of NOx, nitric acid, acid gases, or halogen compound fumes.
Allow warm-up according to the table below. At least 24 hours is recommended if the system hasn't been used for a week or so. This is because the sensor can absorb VOCs when it is not in use.
OEM-2 OEM OZONE CONTROLLER SPECIFICATIONS:
Sensor |
Heated metal oxide semiconductor. |
Range |
0-0.1 ppm, 0-1 ppm and 0-10 ppm available. |
Accuracy |
20%. |
Sensitivity |
As low as 0.02 ppm for the 0.1 ppm module, 0.1 ppm for the 1 ppm module, and 0.3 ppm for the 10 ppm module. These sensitivities will decrease if sensor module extension cables are used. |
Response time |
Within 10's of seconds. |
Turn-on, turn-off time delay |
8 seconds standard. Other times by request. |
Temperature and humidity range |
The calibration is only valid for normal room temperature and humidity. The circuit does not include temperature or humidity compensation devices. |
Supply voltage required |
12-24 VDC or AC, 250 mA. |
Relay ratings |
SPDT non-latching. Contacts:5 amps at 250 volts AC. |
Size of main board |
83 X 83 mm (3.25" X 3.25"). Requires 23 mm (.875") clearance from top surface of board and 6 mm (.250") clearance from bottom surface of the board. |
Main board mounting |
By 4 3.5 mm screws (or 6-32 screws). |
Sensor Module |
16 mm (dia) X 45 mm (length), (.62" X 1.75"), 10 g (0.3 oz) |
Shipping weight |
Both modules and 2 meter sensor extension cable, no adapter454 g (1 lb) |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Pre-calibrated module for combustible gas
-