Infrared Gas Analysis Module
-
Price
Price on request ≥1piece
-
Model Number
RL-H150 -
Data Sheet
-
Package
Original packaging -
Specs
RL-H150 -
Quantity
- +Send Inquiry
Find Similar Products
-
CO Gas Alarm for CO Detection
Model Number:GT
MOQ:1
-
Combustible, Explosive and Toxic Gas Leak Alarm
Model Number:GK
MOQ:1
-
Natural Gas, CO Leakage Detection with Plug
Model Number:GS
MOQ:1
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
Model Number:KAD
MOQ:1
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
Model Number:Venus
MOQ:1
-
Combustible Gas Alarm with EN50194 Approval
Model Number:KAB
MOQ:1
Product Description
RL-H150 Infrared Gas Analysis Module Applications:
It is widely used in gas analysis in cement and metallurgical industry, greenhouse and scientific laboratory gas analysis in greenhouse, chemical fertilizer and chemical industry, gas analysis in industrial process, gas composition gas analysis in flue gas, environmental monitoring, medical monitoring, exhaust analysis, etc.
RL-H150 Infrared Gas Analysis Module Features:
• Design of imported light source and dual-channel detector, built-in temperature compensation, with long life, high precision, fast response,good stability and so on
• Small module, compact structure, easy to install
• Advanced technology, high cost-performance
RL-H150 Infrared Gas Analysis Module Technical parameters:
Measurement principle: NDIR principle
Measurement components and ranges:
RL-H150 measurement components and ranges |
|||
Gas component |
model number |
measuring range |
remarks |
CO2 |
RL-H150CO2 |
0~10%/30%/50%/100% |
Range optional |
CO |
RL-H150CO |
0~10%/30%/50%/100% |
Range optional |
CH4 |
RL-H150CH4 |
0~10%/30%/50%/100% |
Range optional |
C3H8 |
RL-H150C3H8 |
0~10%/30%/50%/100% |
Range optional |
SF6 |
RL-H150SF6 |
0~10%/30%/50%/100% |
Range optional |
NH3 |
RL-H150NH3 |
0~10%/30%/50%/100% |
Range optional |
Resolution :0.01 per cent (based on range of measurements)
Linear error:FS;±2 per cent
Stability:zero drift ±2% FS;
range drift ±2% FS;
Repeatability: FS;±1 per cent;
Sample gas flow:200~800 ml/ min;
Response time:T90≤10 seconds;
Working voltage:6 VDC±5;
Drive current: less than 140 MA;
Air intake mode:continuous air intake;
Sample gas temperature:0℃~+50℃;
Working environment: temperature:-10℃~+50℃
Humidity:≤90 per cent;
Preheat time:3 min;
Mode of communication:sensor with digital output Modbus ASCII 3.3VDC TTL, can achieve two-way communication with computer ;(external output board output 4-20 mA or RS485)
Shape size:RL-H150:62mm( length)×33 mm( width)