Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode
-
Price
Price on request ≥1piece
-
Model Number
H2S-B4 -
Data Sheet
-
Package
Original packaging -
Specs
H2S-B4 -
Quantity
- +Send Inquiry
Find Similar Products
-
Hydrogen Sulfide Sensor (H2S Sensor)
Model Number:H2S-A1
MOQ:1
-
Low Consumption Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME4-H2S
MOQ:1
-
Electrochemical Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME3-H2S
MOQ:1
-
15x15 H2S Sensor 50 ppm Package 110-304
Model Number:3SP_H2S_50 C
MOQ:1
-
P-Type Metal Oxide Hydrogen Sulfide Sensor
Model Number:H2S-MFF, H2S-PFF, H2S-AFF
MOQ:1
-
Miniature Size Hydrogen Sulfide Sensor
Model Number:H2S-D4
MOQ:1
Product Description
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
Sensors are available in the following sizes:
A: 20mm diameter, the industry standard size for portable gas detectors
B: 32mm diameter package, the best choice for fixed site applications
D: miniature, with proven long-term performance. Sensors for the next generation of portable gas detectors
With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE | ||
Sensitivity | nA/ppm at 2ppm H2S | 1450 to 2150 |
Response time | t90 (s) from zero to 2ppm H2S | < 55 |
Zero current | nA in zero air at 20℃ | -250 to 200 |
Noise* | ±2 standard deviations (ppb equivalent) | 1 |
Range | ppm H2S limit of performance warranty | 100 |
Linearity | ppb error at full scale, linear at zero and 40ppm H2S | < ±4 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
* Tested with Alphasense ISB low noise circuit |
|
|
|
|
|
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME | ||
Zero drift | ppb equivalent change/year in lab air | < ±100 |
Sensitivity | drift % change/year in lab air, monthly test | < 20 |
Operating life | months until 50% original signal (24 month warranted) | > 24 |
|
|
|
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL | ||
Sensitivity @ -20℃ | (% output @ -20°C/output @ 20℃) @ 2ppm H2S | 77 to 90 |
Sensitivity @ 50℃ | (% output @ 50°C/output @ 20℃) @ 2ppm H2S | 100 to 110 |
Zero @ -20℃ | nA change from 20℃ |
50 to 60 |
Zero @ 50℃ | nA change from 20℃ |
-120 to -160 |
|
|
|
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY | ||
NO2 sensitivity | % measured gas @ 5ppm NO2 | < -10 |
Cl2 sensitivity | % measured gas @ 5ppm Cl2 | < -12 |
NO sensitivity | % measured gas @ 5ppm NO | < 12 |
SO2 sensitivity | % measured gas @ 5ppm SO2 | < 20 |
CO sensitivity | % measured gas @ 5ppm CO | < 3 |
H2 sensitivity | % measured gas @ 100ppm H2 | < 0.5 |
C2H4 sensitivity | % measured gas @ 100ppm C2H4 | < 0.1 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | < 0.1 |
CO2 sensitivity | % measured gas @ 5% CO2 | < 0.1 |
|
|
|
H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS | ||
Temperature range | ℃ | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh | 15 to 90 |
Storage period | months @ 3 to 20℃ (stored in sealed pot) | 6 |
Load resistor | Ω (ISB circuit is recommended) | 33 to 100 |
Weight | g | < 13 |
Matched Transmitter board for H2S-B4 H2S Sensor

Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
The Individual Sensor Board (ISB) is designed for use with the Alphasense B4 family of four-electrode gas sensors. This potentiostat provides a dual channel voltage output.
A low noise bandgap provides the bias voltage for NO sensors and the ISB can measure both oxidising (CO, H2S, SO2 and NO) and reducing (O3 and NO2) gases.
The ISB is configured for specific sensors: NO, NO2, O3 and CO / H2S / SO2 .
Designed for low power applications, the ISB requires 3.5 to 6.4 stable DC supply at only 1mA.