Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode
-
Price
Price on request ≥1piece
-
Model Number
H2S-A4 -
Data Sheet
-
Package
Original packaging -
Specs
H2S-A4 -
Quantity
- +Send Inquiry
Find Similar Products
-
Hydrogen Sulfide Sensor (H2S Sensor)
Model Number:H2S-A1
MOQ:1
-
Low Consumption Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME4-H2S
MOQ:1
-
Electrochemical Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME3-H2S
MOQ:1
-
15x15 H2S Sensor 50 ppm Package 110-304
Model Number:3SP_H2S_50 C
MOQ:1
-
P-Type Metal Oxide Hydrogen Sulfide Sensor
Model Number:H2S-MFF, H2S-PFF, H2S-AFF
MOQ:1
-
Miniature Size Hydrogen Sulfide Sensor
Model Number:H2S-D4
MOQ:1
Product Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
H2S-A4 Hydrogen Sulfide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.
H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE |
||
Sensitivity |
nA/ppm at 2ppm H2S |
1400 to 1850 |
Response time |
t90 (s) from zero to 2ppm H2S |
< 45 |
Zero current |
nA in zero air at 20°C |
-250 to 100 |
Noise* |
±2 standard deviations (ppb equivalent) |
5 |
Range |
ppm H2S limit of performance warranty |
50 |
Linearity |
ppb error at full scale, linear at zero and 10ppm H2S |
< ± 0.5 |
Overgas limit |
maximum ppm for stable response to gas pulse |
100 |
* Tested with Alphasense AFE low noise circuit |
||
|
|
|
H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME |
||
Zero drift |
ppb equivalent change/year in lab air |
< ±100 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 20 |
Operating life |
months until 50% original signal (24 month warranted) |
24 |
|
|
|
H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL |
||
Sensitivity @ -20°C |
(% output @ -20°C/output @ 20°C) @ 2ppm H2S |
80 to 92 |
Sensitivity @ 50°C |
(% output @ 50°C/output @ 20°C) @ 2ppm H2S |
100 to 110 |
Zero @ -20°C |
nA change from 20°C |
30 to 50 |
Zero @ 50°C |
nA change from 20°C |
90 to 110 |
|
|
|
H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY |
||
NO2 sensitivity |
% measured gas @ 5ppm NO2 |
< -20 |
Cl2 sensitivity |
% measured gas @ 5ppm Cl2 |
< -8 |
NO sensitivity |
% measured gas @ 5ppm NO |
< 3 |
SO2 sensitivity |
% measured gas @ 5ppm SO2 |
< 15 |
CO sensitivity |
% measured gas @ 5ppm CO |
< 1 |
H2 sensitivity |
% measured gas @ 100ppm H2 |
< 0.5 |
C2H4 sensitivity |
% measured gas @ 100ppm C2H4 |
< 0.5 |
NH3 sensitivity |
% measured gas @ 5ppm NH3 |
< 0.1 |
CO2 sensitivity |
% measured gas @ 5% CO2 |
< 0.1 |
|
|
|
H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS |
||
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
% rh |
15 to 90 |
Storage period |
months @ 3 to 20℃ (stored in sealed pot) |
6 |
Load resistor |
Ω (AFE circuit is recommended) |
33 to 100 |
Weight |
g |
< 6 |
Matched Transmitter board for H2S-A4 H2S Sensor
Analogue Front End (AFE) Alphasense A4 Air Quality Sensors
The family of Analogue Front End (AFE) circuits are designed for use with the A4 air quality sensors. Connect the AFE with A4 sensors to your multtiplexed ADC and you are recording air quality data immediately.