Hydrogen Sulfide (H2S) Gas Sensor
-
Price
Price on request ≥1piece
-
Model Number
MICROceL HS -
Data Sheet
-
Package
Original packaging -
Specs
MICROceL HS -
Quantity
- +Send Inquiry
Find Similar Products
-
Hydrogen Sulfide Sensor (H2S Sensor)
Model Number:H2S-A1
MOQ:1
-
Low Consumption Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME4-H2S
MOQ:1
-
Electrochemical Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME3-H2S
MOQ:1
-
15x15 H2S Sensor 50 ppm Package 110-304
Model Number:3SP_H2S_50 C
MOQ:1
-
P-Type Metal Oxide Hydrogen Sulfide Sensor
Model Number:H2S-MFF, H2S-PFF, H2S-AFF
MOQ:1
-
Miniature Size Hydrogen Sulfide Sensor
Model Number:H2S-D4
MOQ:1
Product Description
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Description
MICRO 3-electrode hydrogen sulphide sensor
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Key Features & Benefits
• A robust hydrogen sulfide sensor suitable for portable life safety applications
• Extremely small size
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Technical Specifications
* Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.
MICRO 3-electrode hydrogen sulphide sensor
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Key Features & Benefits
• A robust hydrogen sulfide sensor suitable for portable life safety applications
• Extremely small size
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Technical Specifications
MEASUREMENT |
|
Operating Principle |
3-electrode electrochemical |
Measurement Range |
0-100 ppm H2S |
Maximum Overload |
1000 ppm H2S |
Filter |
To remove TLV levels of
interfering gases |
Sensitivity* |
0.105 ± 0.025 µA/ppm |
T50 Response Time* |
<10 Seconds at 20°C |
Typical T90 Response Time |
25 to 40 seconds |
Baseline Offset (clean air)* |
-2 to +1 ppm H2S equivalent |
Maximum Zero Shift*
(+20°C to +40°C) |
<0.2 ppm H2S equivalent |
Linearity |
Linear up to 1000 ppm H2S |
|
|
ELECTRICAL |
|
Recommended Load Resistor |
10 Ω |
Bias Voltage |
Not Required |
|
|
MECHANICAL |
|
Weight |
1.2 g |
Housing Material |
ABS |
Orientation |
Any |
|
|
ENVIRONMENTAL |
|
Operating Temperature Range |
-40°C to +50°C |
Recommended Storage Temp |
0°C to 20°C |
Operating Pressure Range |
Atmospheric ± 10% |
Operating Humidity Range |
15 - 90% RH non-condensing |
|
|
LIFETIME |
|
Expected Operating Life |
Two years in air |
Long Term Output Drift |
<5% signal loss per year |
Storage Life |
6 months in CTL container |