High Concentration Hydrogen Sulfide Sensor (H2S Sensor)
-
Price
Price on request ≥1piece
-
Model Number
H2S-AE -
Data Sheet
-
Package
Original packaging -
Specs
H2S-AE -
Quantity
- +Send Inquiry
Find Similar Products
-
Hydrogen Sulfide Sensor (H2S Sensor)
Model Number:H2S-A1
MOQ:1
-
Low Consumption Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME4-H2S
MOQ:1
-
Electrochemical Hydrogen Sulfide Sensor H2S Sensor
Model Number:ME3-H2S
MOQ:1
-
15x15 H2S Sensor 50 ppm Package 110-304
Model Number:3SP_H2S_50 C
MOQ:1
-
P-Type Metal Oxide Hydrogen Sulfide Sensor
Model Number:H2S-MFF, H2S-PFF, H2S-AFF
MOQ:1
-
Miniature Size Hydrogen Sulfide Sensor
Model Number:H2S-D4
MOQ:1
Product Description
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
H2S-AE Hydrogen Sulfide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.
Matched Transmitter board for H2S-AE H2S Sensor

4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
H2S-AE Hydrogen Sulfide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE |
||
Sensitivity |
nA/ppm in 400ppm H2S |
65 to 110 |
Response time |
t90 (s) from zero to 400ppm H2S |
< 25 |
Zero current |
ppm equivalent in zero air |
< ±3 |
Resolution |
RMS noise (ppm equivalent) |
< 0.5 |
Range |
ppm H2S limit of performance warranty |
2,000 |
Linearity |
ppm error at full scale, linear at zero and 400ppm H2S |
0 to -40 |
Overgas limit |
maximum ppm for stable response to gas pulse |
10,000 |
|
|
|
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
nd |
Sensitivity drift |
% change/year in lab air, monthly test |
nd |
Operating life |
months until 80% original signal (24 month warranted) |
> 24 |
|
|
|
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL |
||
Sensitivity @ -20°C |
% (output @ -20°C/output @ 20°C) @ 20ppm |
80 to 92 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 20ppm |
100 to 110 |
Zero @ -20°C |
ppm equivalent change from 20°C |
< ±1 |
Zero @ 50°C |
ppm equivalent change from 20°C |
< ±1 |
|
|
|
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY |
||
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< -20 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< -15 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 20 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
< 20 |
CO sensitivity |
% measured gas @ 400ppm CO |
< 4 |
H2 sensitivity |
% measured gas @ 400ppm H2 |
< 1 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 0.1 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 0.1 |
|
|
|
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS |
||
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
% rh continuous |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 6 |
Matched Transmitter board for H2S-AE H2S Sensor

4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change