• Flammable Gas Sensors Used for Gas Setectors and Leak Testers
Mouse over image to zoom

Flammable Gas Sensors Used for Gas Setectors and Leak Testers

ISweek online 2h ago

Shenzhen Isweek Technology Co., Ltd

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    NAP-66A
  • Data Sheet

  • Package

    Original packaging
  • Specs

    NAP-66A
  • Quantity

    - +
  • Send Inquiry

Product Description

NAP-66A is mainly used for gas detectors and leak testers. NAP-66A is a half in height and needs a half in power consumption compared to existing sensor so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual user’s manual for further information.


* Target gases and concentration

Gases

Detection range

Propane

C3H8

0.03~ 2.2% (0.03~ 1%)

Iso-butane

Iso-C4H10

0.03~ 1.8% (0.03~ 0.8%)

Hydrogen

H2

0.05~ 4%  (0.05~ 1.5%)

Ethanol

C2H5OH

0.05~ 3.2% (0.05~ 1.5%)

Hydrocarbons 

 CnH2n+2

1~100% LEL (1~50%LEL)

( ) is a detection range in high accuracy


* Ratings 

Items
Ratings
Supply Voltage

DC 2.0 ± 0.2V

AC 2.0 ± 0.2V (r.m.s. 50~60Hz)

Current (When 2.0V is applied)

DC 140 ~ 160mA

AC 140 ~ 160mA (r.m.s. 50~60Hz)

Ambient Temperature

In operation -10 ~ +50℃

In storage -10 ~ +50℃

Ambient humidity

In operation 95%RH or less

In storage 99%RH or less (No dew condensation)


* Gas sensitivity characteristics 

Gases and concentration
Output voltage
Output in clean air
-35 ~ +35mV
Iso-butane 1400ppm
10 ~ 15mV
Hydrogen 1400ppm
7 ~ 12mV
Ethanol 1400ppm
Less than 11mV

Structure & appearance of NAP-66A