• Operating Principle: 3-electrode electrochemical
• Measurement Range: 0-20 ppm SO2
• Maximum Overload: 100 ppm SO2
• Filter: None
• Sensitivity: 1.25 ± 0.25 µA/ppm
• Response Time (T90): <15 Seconds
• Resolution: 0.1 ppm
• Repeatability: 2% of signal
• Linearity: Linear
- Quantity:
- - +
Product Specification
7SH CiTiceL Sulfur Dioxide Sensor (SO2 Sensor) Key Features & Benefits:
• Robust, industry standard 7-Series packaging
• Compact Size
7SH CiTiceL Sulfur Dioxide Sensor (SO2 Sensor) Technical Specifications
MEASUREMENT | |
Operating Principle | 3-electrode electrochemical |
Measurement Range | 0-20 ppm SO2 |
Maximum Overload | 100 ppm SO2 |
Filter | None |
Sensitivity* | 1.25 ± 0.25 µA/ppm |
Response Time (T90)* | <15 Seconds |
Baseline Offset (clean air)* | -0.1 to +0.2 ppm SO2 equivalent |
Zero Shift (+20°C to +40°C) | < 0.1 ppm SO2 equivalent |
Resolution | 0.1 ppm (when used with recommended electronics) |
Repeatability | 2% of signal |
Linearity | Linear |
ELECTRICAL | |
Recommended Load Resistor | 10 Ω |
Bias Voltage | Not Required |
MECHANICAL | |
Weight | 17 g |
Housing Material: | |
Cap | Polycarbonate |
Body | ABS |
Orientation | Any |
ENVIRONMENTAL | |
Operating Temperature Range | -20°C to +50°C |
Recommended Storage Temp | 0°C to 20°C |
Operating Pressure Range | Atmospheric ± 10% |
Operating Humidity Range | 15 - 90% RH non-condensing |
LIFETIME | |
Long Term Sensitivity Drift | <2% signal loss/month |
Expected Operating Life | Two years in air |
Storage Life | 6 months in CTL container |
* Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.
Poisoning
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)