Electrochemical Ammonia Sensor (NH3 Sensor) with Fast Response - NH3/MR-100
• Nominal Range: 0 - 100 ppm
• Maximum Overload: 200 ppm
• Expected Operation Life: 2 years in air
• Output Signal: 110 ± 30 nA/ppm
• Resolution: 1 ppm
• Repeatability: < 3 % of signal
• T90 Response Time: < 40 sec
• Temperature Range: -10°C to 40°C
• Relative Humidity Range: 15 % to 90 % R.H. non-condensing
- Quantity:
- - +
Product Specification
Miniature Gas Sensors
Industry standard for portable gas detectors. Widely-used format for personal safety.
Features
Smallest size
Dimensions
Conforms to 4-Series
Diameter: 20 mm
Height: 16.6 mm
Pin diameter: 1.5 mm
NH3/MR-100 Ammonia Sensor (NH3 Sensor) Applications
• Leak Detection
• Safety and Environmental Control
• For Portable Gas Detectors
NH3/MR-100 Ammonia Sensor (NH3 Sensor) Performance Characteristics
Performance data conditions: 20°C, 50% RH and 1013 mbar
Nominal Range |
0 - 100 ppm |
Maximum Overload |
200 ppm |
Expected Operation Life |
2 years in air |
Output Signal |
110 ± 30 nA/ppm |
Resolution |
1 ppm |
Temperature Range |
-10°C to 40°C |
Pressure Range |
Atmospheric |
Pressure Coefficient |
No data |
T90 Response Time |
< 40 sec |
Relative Humidity Range |
15 % to 90 % R.H. non-condensing |
Baseline |
0 ppm ± 3 ppm |
Maximum Zero Shift (+20°C to +40°C) |
-8 ppm |
Typical Long Term Output Drift |
< 5% per 6 months |
Recommended Load Resistor |
10 Ohm |
Bias Voltage |
Not allowed |
Repeatability |
< 3 % of signal |
Output Linearity |
< 5 % of scale |
Humidity Effect |
< 4 ppm |
NH3/MR-100 Ammonia Sensor (NH3 Sensor) Physical Characteristics
Weight |
~ 5.4 g |
Position Sensitivity |
None |
Storage Life |
Six months in container |
Recommended Storage Temperature |
5°C - 20°C |
Warranty Period |
12 months from date of dispatch |
NH3/MR-100 Ammonia Sensor (NH3 Sensor) Cross Sensitivity Data
Interfering Gas |
Concentration |
Reading |
CO |
300 ppm |
0 ppm |
H2 |
200 ppm |
0 ppm |
SO2 |
20 ppm |
-7 ppm |
H2S |
20 ppm |
7 ppm |
NO |
20 ppm |
-1 ppm |
NO2 |
20 ppm |
-20 ppm |
Cl2 | 20 ppm | -55 ppm |
CO2 |
2% |
0 ppm |
SiH4 |
10 ppm |
0 ppm |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)