Dissolved Oxygen Probe
-
Price
Price on request ≥1piece
-
Model Number
ENV-40-DO -
Data Sheet
-
Package
Original packaging -
Specs
ENV-40-DO -
Quantity
- +Send Inquiry
Find Similar Products
-
Laboratory Dissolved Oxygen Sensor
Model Number:DO1200
MOQ:1
-
Submersible Galvanic Dissolved Oxygen Sensor
Model Number:DO6400/DO7400 Series
MOQ:1
-
UVT-LED Sensor UV Transmittance Sensor
Model Number:UVT-LED
MOQ:1
-
4-20mA Dissolved Oxygen Transmitters
Model Number:DOMA-10/DOMA-20
MOQ:1
-
Dissolved Oxygen Sensor for Oxygen Measurement
Model Number:SE 706
MOQ:1
-
Memosens Oxygen Sensor
Model Number:SE 715
MOQ:1
Product Description
ENV-40-DO Dissolved Oxygen Probe Operating principle
A galvanic dissolved oxygen probe consists of a polyethylene membrane, an anode bathed in an electrolyte and a cathode. Oxygen molecules defuse through the probes membrane at a constant rate (without the membrane the reaction happens to quickly). Once the oxygen molecules have crossed the membrane they are reduced at the cathode and a small voltage is produced. If no oxygen molecules are present, the probe will output 0 mV. As the oxygen increases so does the mV output from the probe. Each probe will output a different voltage in the presence of oxygen. The only thing that is constant is that 0mV = 0 Oxygen. (A galvanic dissolved oxygen probe can also be used to detect the Oxygen content in gases).
This Dissolved Oxygen probe can be fully submerged in fresh or salt water, up to the BNC connector indefinitely.
ENV-40-DO Dissolved Oxygen Probe Typical Applications
• Standard Lab use
• Field use
• Hydroponics
• Fish keeping
• Wine making
• Food Safe
• Environmental monitoring
ENV-40-DO Dissolved Oxygen Probe Specifications
A galvanic dissolved oxygen probe consists of a polyethylene membrane, an anode bathed in an electrolyte and a cathode. Oxygen molecules defuse through the probes membrane at a constant rate (without the membrane the reaction happens to quickly). Once the oxygen molecules have crossed the membrane they are reduced at the cathode and a small voltage is produced. If no oxygen molecules are present, the probe will output 0 mV. As the oxygen increases so does the mV output from the probe. Each probe will output a different voltage in the presence of oxygen. The only thing that is constant is that 0mV = 0 Oxygen. (A galvanic dissolved oxygen probe can also be used to detect the Oxygen content in gases).
This Dissolved Oxygen probe can be fully submerged in fresh or salt water, up to the BNC connector indefinitely.
ENV-40-DO Dissolved Oxygen Probe Typical Applications
• Standard Lab use
• Field use
• Hydroponics
• Fish keeping
• Wine making
• Food Safe
• Environmental monitoring
ENV-40-DO Dissolved Oxygen Probe Specifications
Reads |
Dissolved Oxygen |
Range |
0 - 100 mg/L |
Response time |
~0.3 mg/L/per sec |
Max pressure |
3,447 kPa (500 PSI) |
Max depth |
343 meters (1,125 ft) |
Temperature range |
1 - 50 °C |
Cable length |
1 meter |
Internal temperature sensor |
No |
Time before recalibration |
~1 Year |
Life expectancy |
5 Years + |
Maintenance |
~18 Months |
Weight |
52 grams |
Dimensions |
16.5mm x 114mm (0.5" x 4.48") |
BNC connector |
Yes |
Sterilization |
Chemical only |
Membrane type |
Teflon |