• Digital Humidity and Temperature Module
Mouse over image to zoom

Digital Humidity and Temperature Module

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    HYT 939
  • Data Sheet

  • Package

    Original packaging
  • Specs

    HYT 939
  • Quantity

    - +
  • Send Inquiry

Product Description

Further advantages of the HYT 939 digital humidity module include:

•  Calibrated and temperature compensated

•  Excellent humidity/temperature accuracy and stability

•  High chemical resistance

•  I2C protocol (address 0x28 or alternative address)

•  Wide humidity and temperature range (0 % RH to 100 % RH and -40 °C to +125 °C)

•  Very low drift

•  Very stable at high humidity

•  Interchangeable without adjustments

•  Pressure-resistant version (up to 16 bar) upon request

 The digital HYT 939 humidity module is suitable for various medical systems, autoclaves, pressure dew point measurement (pressure tight packaging required), drying systems and laboratory applications.

 

Technical Data:

Operating temperature range

-40to +125

Operating humidity range

0 % RH to 100 % RH

Hysteresis

< ±1 % RH

Linearity error

< ±1 % RH

Temperature error

0.05 % RH/K (0to +60)

Operating voltage

2.7 V to 5.5 V

Current consumption (nominal)

< 22 µA at 1 Hz measuring rate; 850 µA max.

Current consumption (sleep)

< 1 µA

Digital interface

I2C, address 0x28 or alternative address

Operating voltage (limits)

-0.3 V to 6 V

Storage condition

-20to +50

 

Humidity

Temperature

Accuracy

±1.8 % RH at +23(0 % RH to 90 % RH)

±0.2 K (0to +60)

Reproducibility

±0.2 % RH

±0.1 K

Resolution

0.02 % RH

0.015

Response time t63

< 10 s with metal mesh filter

< 10 s with metal mesh filter

Long-term drift

< 0.5 % RH/a (at +23and 30 % RH to 70 % RH - laboratory

conditions)

< 0.05 K/a

Measuring principle

Capacitive polymer humidity sensor

PTAT (integrated)

 

Further advantages of the IST AG HYT LabKit include:

•  Dew/frost point calculation and further humidity parameters

•  Plug-in connection adapter included

•  Evaluation software RECORDER and PCLOG for Windows included